Lucene search
+L

8 matches found

RedhatCVE
RedhatCVE
•added 2025/05/22 10:31 a.m.•20 views

CVE-2019-14359

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

2.4CVSS5.4AI score0.00423EPSS
SaveExploits1References1
CNVD
CNVD
•added 2019/08/13 12:00 a.m.•11 views

BC Vault Information Disclosure Vulnerability

BC Vault is an e-wallet device for storing cryptocurrencies. An information disclosure vulnerability exists in BC Vault. The vulnerability stems from errors such as configuration during operation of a networked system or product. An unauthorized attacker could exploit the vulnerability to obtain...

2.4CVSS6.2AI score0.00423EPSS
SaveExploits1References1
NVD
NVD
•added 2019/08/12 11:15 p.m.•32 views

CVE-2019-14359

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

2.4CVSS3.3AI score0.00423EPSS
SaveExploits1References1
Prion
Prion
•added 2019/08/12 11:15 p.m.•23 views

Code injection

DISPUTED On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might...

2.1CVSS3.6AI score0.00423EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2019/08/12 10:31 p.m.•45 views

CVE-2019-14359

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

3.3AI score0.00423EPSS
SaveExploits1References1
CVE
CVE
•added 2019/08/12 10:31 p.m.•79 views

CVE-2019-14359

CVE-2019-14359 describes a side-channel on BC Vault devices where the power usage per row of the SSD1309 OLED display leaks information about the number of illuminated pixels. The practical impact is limited: an attacker would need control over the device’s USB connection to measure power while s...

2.4CVSS3.5AI score0.00423EPSS
SaveExploits1References1Affected Software1
Positive Technologies
Positive Technologies
•added 2019/08/12 12:00 a.m.•17 views

PT-2019-13638 · Bc Vault · Bc Vault

Name of the Vulnerable Software and Affected Versions: BC Vault affected versions not specified Description: A side channel was discovered related to the row-based SSD1309 OLED display on BC Vault devices. The power consumption during each display cycle varies based on the number of illuminated...

2.4CVSS6.7AI score0.00423EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/08/12 12:00 a.m.•8 views

CVE-2019-14359: Observable Discrepancy

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

2.4CVSS5.8AI score0.00423EPSS
SaveExploits1References2
Rows per page
Query Builder