Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37376)
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Siemens Desigo PXC and DXR Devices Uncontrolled Resource Consumption Vulnerability
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Siemens Desigo PXC and DXR Devices Remote Code Execution Vulnerability
The Desigo PXC4 building automation controller is designed for HVAC system control. It is a compact device with built-in IOs that can be expanded to meet your needs with additional TX-IO modules.The Desigo PXC5 is a freely programmable controller for BACnet system-level functions such as alarm...
Siemens Desigo DXR和PXC Controllers拒绝服务漏洞
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-36376)
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37375)
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37374)
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Siemens Desigo PXC and DXR Devices have unspecified vulnerabilities
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
CVE-2021-41545
A vulnerability has been identified in Desigo DXR2 All versions V01.21.142.5-22, Desigo PXC3 All versions V01.21.142.4-18, Desigo PXC4 All versions V02.20.142.10-10884, Desigo PXC5 All versions V02.20.142.10-10884. When the controller receives a specific BACnet protocol packet, an exception cause...
Design/Logic Flaw
A vulnerability has been identified in Desigo DXR2 All versions V01.21.142.5-22, Desigo PXC3 All versions V01.21.142.4-18, Desigo PXC4 All versions V02.20.142.10-10884, Desigo PXC5 All versions V02.20.142.10-10884. When the controller receives a specific BACnet protocol packet, an exception cause...
CVE-2021-41545
CVE-2021-41545 affects Siemens Desigo DXR2, PXC3, PXC4 and PXC5 controllers. When a device receives a specific BACnet packet, an exception can cause the BACnet communication function to enter an out-of-work state, potentially leading to a factory reset. Affected versions are: DXR2 all versions be...
CVE-2021-41545
A vulnerability has been identified in Desigo DXR2 All versions V01.21.142.5-22, Desigo PXC3 All versions V01.21.142.4-18, Desigo PXC4 All versions V02.20.142.10-10884, Desigo PXC5 All versions V02.20.142.10-10884. When the controller receives a specific BACnet protocol packet, an exception cause...
多款Siemens产品安全漏洞
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Siemens Climatix POL909 (AWM and AWB) Cross-Site Scripting Vulnerability (CNVD-2022-17788)
Siemens Climatix AWB Advanced Web and BACnet Module, POL909 enables users of the Climatix 600 solution to connect to a BACnet IP network and implement and load customer web pages and features. Siemens Climatix AWM Advanced Web Module, POL909 enables users of the Climatix 600 solution to implement...
Siemens Climatix Pol909 日志信息泄露漏洞
Siemens Climatix AWB Advanced Web and BACnet Module, POL909 enables users of the Climatix 600 solution to connect to a BACnet IP network and implement and load customer web pages and features. Siemens Climatix AWM Advanced Web Module, POL909 enables users of the Climatix 600 solution to implement...
Climatix POL909 跨站脚本漏洞
Siemens Climatix AWB Advanced Web and BACnet Module, POL909 enables users of the Climatix 600 solution to connect to a BACnet IP network and implement and load customer web pages and features. Siemens Climatix AWM Advanced Web Module, POL909 enables users of the Climatix 600 solution to implement...
Siemens Nucleus RTOS-based APOGEE and TALON Products Improper Null Termination (CVE-2021-31884)
A vulnerability has been identified in APOGEE MBC PPC BACnet All versions, APOGEE MBC PPC P2 Ethernet All versions, APOGEE MEC PPC BACnet All versions, APOGEE MEC PPC P2 Ethernet All versions, APOGEE PXC Compact BACnet All versions = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and...
Siemens BACnet Field Panels Authentication Bypass Using an Alternate Path or Channel (CVE-2017-9946)
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions V3.5. An attacker with network access to the integrated web server 80/tcp and 443/tcp could bypass the authentication and download sensitive information from the device. This plugi...
Siemens BACnet Field Panels Improper Limitation of a Pathname to a Restricted Directory (CVE-2017-9947)
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server 80/tcp and 443/tcp to obtain information on the structure o...
Design/Logic Flaw
A vulnerability has been identified in APOGEE MBC PPC BACnet All versions, APOGEE MBC PPC P2 Ethernet All versions, APOGEE MEC PPC BACnet All versions, APOGEE MEC PPC P2 Ethernet All versions, APOGEE PXC Compact BACnet All versions = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and = V2.3 and...