Lucene search
+L

154 matches found

OSV
OSV
•added 2021/09/24 9:15 p.m.•10 views

CVE-2021-40655

An informtion disclosure issue exists in D-LINK-DIR-605 B2 Firmware Version : 2.01MT. An attacker can obtain a user name and password by forging a post request to the / getcfg.php page...

7.5CVSS5.8AI score0.86659EPSS
SaveExploits1References3
NVD
NVD
•added 2021/09/24 9:15 p.m.•26 views

CVE-2021-40655

An informtion disclosure issue exists in D-LINK-DIR-605 B2 Firmware Version : 2.01MT. An attacker can obtain a user name and password by forging a post request to the / getcfg.php page...

7.5CVSS0.86659EPSS
SaveExploits1References3
CVE
CVE
•added 2021/09/24 8:11 p.m.•252 views

CVE-2021-40655

CVE-2021-40655 affects the D-Link DIR-605 series (DIR-605/B2, firmware 2.01MT). The issue is an information-disclosure vulnerability where an unauthenticated attacker can obtain a router username and password by forging a POST request to the /getcfg.php endpoint. The NVD/Nuclei/NASL/NIST referenc...

7.5CVSS7.4AI score0.86659EPSS
SaveIn wildExploits1References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/09/24 12:00 a.m.•4 views

CVE-2021-40655: Incorrect Authorization

An informtion disclosure issue exists in D-LINK-DIR-605 B2 Firmware Version : 2.01MT. An attacker can obtain a user name and password by forging a post request to the / getcfg.php page...

7.5CVSS5.8AI score0.86659EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/09/24 12:00 a.m.•5 views

CVE-2021-40654: Incorrect Authorization

An information disclosure issue exist in D-LINK-DIR-615 B2 2.01mt. An attacker can obtain a user name and password by forging a post request to the / getcfg.php page...

6.5CVSS5.8AI score0.01859EPSS
SaveExploits1References2
CNVD
CNVD
•added 2020/06/28 12:00 a.m.•19 views

Denial of Service Vulnerability in ZoomInnovation Conexant C2000-B2-SFE0101-BB1 Serial Server

The C2000-B2-SFE0101-BB1 Serial Server is a serial device networking server. A denial of service vulnerability exists in the ZoomInnovation Conexant C2000-B2-SFE0101-BB1 Serial Server, which can be exploited by an attacker to cause a denial of service...

6.7AI score
SaveExploits0
NVD
NVD
•added 2020/04/20 11:15 p.m.•28 views

CVE-2020-9278

An issue was discovered on D-Link DSL-2640B B2 EU4.01B devices. The device can be reset to its default configuration by accessing an unauthenticated URL...

9.1CVSS9.3AI score0.01623EPSS
SaveExploits1References3
Prion
Prion
•added 2020/04/20 11:15 p.m.•25 views

Stack overflow

An issue was discovered on D-Link DSL-2640B B2 EU4.01B devices. The function docgi, which processes cgi requests supplied to the device's web servers, is vulnerable to a remotely exploitable stack-based buffer overflow. Unauthenticated exploitation is possible by combining this vulnerability with...

9CVSS9.3AI score0.02601EPSS
SaveExploits2References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/20 12:00 a.m.•10 views

CVE-2020-9279: Use of Hard-coded Credentials

An issue was discovered on D-Link DSL-2640B B2 EU4.01B devices. A hard-coded account allows management-interface login with high privileges. The logged-in user can perform critical tasks and take full control of the device...

10CVSS8.1AI score0.02187EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/20 12:00 a.m.•8 views

CVE-2020-9277: Improper Authentication

An issue was discovered on D-Link DSL-2640B B2 EU4.01B devices. Authentication can be bypassed when accessing cgi modules. This allows one to perform administrative tasks e.g., modify the admin password with no authentication...

9.8CVSS8.1AI score0.02464EPSS
SaveExploits1References2
CNVD
CNVD
•added 2019/11/18 12:00 a.m.•10 views

Denial of Service Vulnerability in C2000-B2-SFE0101-BB1 Serial Port Server

The C2000-B2-SIE0101-BB1 is an industrial-grade serial device networking server. A denial of service vulnerability exists in the C2000-B2-SFE0101-BB1 serial server that can be exploited by an attacker to cause the server to deny service...

6.8AI score
SaveExploits0
Openbugbounty
Openbugbounty
•added 2019/10/26 10:22 p.m.•19 views

b2.astrosage.com Cross Site Scripting vulnerability

Open Bug Bounty ID: OBB-1004174 Following coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: &nbsp&nbsp&nbsp&nbsp&nbsp&nbspa. verified the vulnerability and confirmed its existence; &nbsp&nbsp&nbsp&nbsp&nbsp&nbspb. notified the website...

6.2AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•14 views

Mitsubishi QJ71E71-B2 Communications Adapter Detection

Binary data 761516.prm...

7.3AI score
SaveExploits0
Openbugbounty
Openbugbounty
•added 2017/11/30 2:53 a.m.•21 views

eservice.gov.bd XSS vulnerability

Open Bug Bounty ID: OBB-442714 Description| Value ---|--- Affected Website:| eservice.gov.bd Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1 CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N Remediation Guide:| OWASP XSS Prevention Cheat...

6.4AI score
SaveExploits0
Oracle linux
Oracle linux
•added 2017/03/08 12:00 a.m.•76 views

firefox security update

45.8.0-2.0.1 - Add firefox-oracle-default-prefs.js and firefox-oracle-default-bookmarks.html and remove the corresponding Red Hat files 45.8.0-2 - Update to 45.8.0 ESR B2 45.8.0-1 - Update to 45.8.0 ESR 45.7.0-2 - Enabled ppc/s390 arches rhbz1418765...

10CVSS1.1AI score0.17273EPSS
SaveExploits9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/02/13 12:00 a.m.•8 views

CVE-2016-8368: Improper Synchronization

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to conne...

8.6CVSS5.9AI score0.02615EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/02/13 12:00 a.m.•8 views

CVE-2016-8370: Use of a Broken or Risky Cryptographic Algorithm

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC...

7.5CVSS5.7AI score0.01312EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2017/02/13 12:00 a.m.•5 views

PT-2017-9644

Name of the Vulnerable Software and Affected Versions Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-B5, all versions Mitsubishi Electric Automation MELSEC-Q seri...

7.5CVSS0.01312EPSS
SaveExploits0References4
CNVD
CNVD
•added 2016/12/03 12:00 a.m.•42 views

Denial of Service Vulnerability in Multiple Mitsubishi Electric MELSEC-Q Series Products

Mitsubishi Electric is a Japanese company. The affected products, QJ71E71-100, QJ71E71-B5 and QJ71E71-B2, are Ethernet interface modules used to connect MELSEC-Q series programmable controllers to host networks. A denial of service vulnerability exists in multiple Mitsubishi Electric MELSEC-Q...

8.6CVSS6.9AI score0.02615EPSS
SaveExploits0References1
CNVD
CNVD
•added 2016/12/01 12:00 a.m.•15 views

Security Bypass Vulnerability in Multiple Mitsubishi Electric MELSEC-Q Series Products

Mitsubishi Electric is a Japanese company. The affected products, QJ71E71-100, QJ71E71-B5 and QJ71E71-B2, are Ethernet interface modules used to connect MELSEC-Q series programmable controllers to host networks. A security bypass vulnerability exists in multiple Mitsubishi Electric MELSEC-Q Serie...

7.5CVSS7AI score0.01312EPSS
SaveExploits0References1
Rows per page
Query Builder