3093 matches found
CVE-2021-35215
Insecure deserialization leading to Remote Code Execution was detected in the Orion Platform version 2020.2.5. Authentication is required to exploit this vulnerability...
PT-2021-7541 · Vmware · Vmware Vrealize Log Insight
Name of the Vulnerable Software and Affected Versions: VMware vRealize Log Insight versions 8.x prior to 8.4 Description: The issue is due to improper user input validation, allowing an attacker with user privileges to inject a malicious payload via the Log Insight UI. This payload would be...
CVE-2021-37597
WP Cerber before 8.9.3 allows MFA bypass via wordpressloggedinhash manipulation...
CVE-2021-3458
The Motorola MM1000 device configuration portal can be accessed without authentication, which could allow adapter settings to be modified...
Information Disclosure
apache-airflow is vulnerable to information disclosure. The logging server running on port 0.0.0.0 by default has no authentication and allows reading log files of DAG jobs...
Siemens Sicam Missing Authentication for Critical Function
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the device's web server might be able to execute administrative commands without authentication. File data ot500430.nasl...
PT-2021-14612 · Dell · Dell Openmanage Enterprise
Name of the Vulnerable Software and Affected Versions: Dell OpenManage Enterprise versions prior to 3.6.1 Description: The issue is related to an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to hijack an elevated session or...
CVE-2021-32002 SiteManager troubleshooter allows access without authentication from local network
Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware...
CVE-2021-21538
Dell EMC iDRAC9 (Dell EMC Remote Access Controller) versions 4.40.00.00 and later are affected by CVE-2021-21538 when prior to 4.40.10.00 due to an improper authentication vulnerability that could allow a remote, unauthenticated attacker to gain access to the iDRAC virtual console. Root cause: im...
CVE-2020-36239
Jira Data Center, Jira Core Data Center, Jira Software Data Center from version 6.3.0 before 8.5.16, from 8.6.0 before 8.13.8, from 8.14.0 before 8.17.0 and Jira Service Management Data Center from version 2.0.2 before 4.5.16, from version 4.6.0 before 4.13.8, and from version 4.14.0 before 4.17....
CVE-2021-26824
DM FingerTool v1.19 in the DM PD065 Secure USB is susceptible to improper authentication by a replay attack, allowing local attackers to bypass user authentication and access all features and data on the USB...
openSUSE 15 Security Update : cryptctl (openSUSE-SU-2021:2136-1)
The remote SUSE Linux SUSE15 host has a package installed that is affected by a vulnerability as referenced in the openSUSE-SU-2021:2136-1 advisory. - A Use of Password Hash Instead of Password for Authentication vulnerability in cryptctl of SUSE Linux Enterprise Server for SAP 12-SP5, SUSE Manag...
CVE-2021-32743
Icinga is a monitoring system which checks the availability of network resources, notifies users of outages, and generates performance data for reporting. In versions prior to 2.11.10 and from version 2.12.0 through version 2.12.4, some of the Icinga 2 features that require credentials for extern...
Schneider Electric EcoStruxure Control Expert 安全漏洞
Schneider Electric EcoStruxure Control Expert formerly known as Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. Schneider Electric EcoStruxure Control Expert has a security vulnerability in several of its products that...
PT-2021-7077 · Schneider Electric · Scadapack Remoteconnect For X70 +4
Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert versions prior to V15.0 SP1 EcoStruxure Process Expert all versions SCADAPack RemoteConnect for x70 all versions Modicon M580 CPU all versions - part numbers BMEP and BMEH Modicon M340 CPU all versions - part number...
The vulnerability of user authentication within the IKE-protocol’s Xauth mechanism, which stems from insufficient validation of input data, allows attackers to trigger service failures.
The vulnerability related to user authentication within the Xauth protocol of the IKE protocol is linked to improper validation during the file transmission to the program’s input. Exploiting this vulnerability allows an attacker to cause service failures...
Jira Data Center & Jira Service Management Data Center - Missing Authentication for Ehcache RMI - CVE-2020-36239
h3. Issue Summary Jira Data Center, Jira Core Data Center, Jira Software Data Center, and Jira Service Management Data Center exposed a Ehcache RMI network service which attackers, who can connect to the service, on port 40001 and potentially 40011 012, could execute arbitrary code of their choic...
AVEVA System Platform 访问控制错误漏洞
AVEVA System Platform is an application from the UK-based AVEVA Aveva. A responsive, standards-driven and scalable foundation for regulatory, enterprise SCADA, MES and IIoT applications.An authentication vulnerability exists in AVEVA System Platform. No details of the vulnerability are currently...
White Shark System (WSS) Sensitive Information Disclosure Vulnerability
White Shark System WSS is a browser-based collaboration platform that integrates Project Management, Task Management, Work Management and Work Log Management. Project Management", "Task Management", "Work Management" and "Work Log Management". A sensitive information disclosure vulnerability exis...
CVE-2021-33842
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located...