15220 matches found
CVE-2024-13813
Insufficient permissions in Ivanti Secure Access Client before version 22.8R1 allows a local authenticated attacker to delete arbitrary files...
CVE-2024-13843
CVE-2024-13843 affects Ivanti Connect Secure and Ivanti Policy Secure prior to versions 22.7R2.6 and 22.7R1.3, respectively. The root issue is the cleartext storage of information, allowing a local authenticated attacker with admin privileges to read sensitive data. Impact is limited to confident...
CVE-2024-13843
Cleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-13843
Cleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-13842
CVE-2024-13842 details: Ivanti Connect Secure prior to 22.7R2.3 (and Ivanti Policy Secure prior to 22.7R1.3) contains a hardcoded key that enables a local, authenticated attacker with admin privileges to read sensitive data. The vulnerability is an information disclosure issue within the admin po...
CVE-2024-13842
A hardcoded key in Ivanti Connect Secure before version 22.7R2.3 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-12058
External control of a file name in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a remote authenticated attacker with admin privileges to read arbitrary files...
CVE-2024-12058
External control of a file name in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a remote authenticated attacker with admin privileges to read arbitrary files...
CVE-2025-23403
Summary (CVE-2025-23403) : Siemens SIMATIC IPC DiagBase and DiagMonitor (All versions) have a vulnerability where user permissions for a registry key are not properly restricted. An authenticated attacker could load vulnerable drivers, leading to privilege escalation or bypassing endpoint protect...
CVE-2025-23403
A vulnerability has been identified in SIMATIC IPC DiagBase All versions, SIMATIC IPC DiagMonitor All versions. The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to...
CVE-2025-23403
A vulnerability has been identified in SIMATIC IPC DiagBase All versions, SIMATIC IPC DiagMonitor All versions. The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to...
CVE-2025-26411
An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web...
CVE-2025-26411 Authenticated Arbitrary Python File Upload via Plugin Manager
An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web...
CVE-2025-23190
Due to missing authorization check, an authenticated attacker could call a remote-enabled function module which allows them to access data that they would otherwise not have access to. The attacker cannot modify data or impact the availability of the system...
CVE-2025-23190 Missing Authorization check in SAP NetWeaver and ABAP platform (ST-PI)
Due to missing authorization check, an authenticated attacker could call a remote-enabled function module which allows them to access data that they would otherwise not have access to. The attacker cannot modify data or impact the availability of the system...
CVE-2025-23190
CVE-2025-23190 affects SAP NetWeaver/ABAP platform (ST-PI). The root cause is a missing authorization check that allows an authenticated attacker to call a remote-enabled function module and access data they normally cannot view. The attacker cannot modify data or affect system availability as de...
Siemens SIMATIC IPC DiagBase 安全漏洞
Siemens SIMATIC IPC DiagBase is a diagnostic software from Siemens, Germany, used to monitor and diagnose the hardware and system status of SIMATIC IPCs industrial computers. A security vulnerability exists in Siemens SIMATIC IPC DiagBase that stems from affected devices not properly restricting...
PT-2025-6314 · Microsoft · Digest Authentication +1
Name of the Vulnerable Software and Affected Versions: Microsoft Digest Authentication affected versions not specified Description: The issue allows remote attackers to execute arbitrary code and affect the system. It is noted that any authenticated attacker could trigger this issue on domain...
Siemens SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor
SUMMARY SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor contain a weak registry permission vulnerability that could allow an authenticated attacker to perform privilege escalation or bypass security measures. Siemens recommends specific countermeasures for products where fixes are not, or not...