Lucene search
K

8 matches found

CNNVD
CNNVD
added 2025/06/11 12:0 a.m.1 views

Siemens SINAMICS PERFECT HARMONY GH180 访问控制错误漏洞

The Siemens SINAMICS PERFECT HARMONY GH180 is a high-voltage AC inverter from Siemens Germany. An access control error vulnerability exists in the Siemens SINAMICS PERFECT HARMONY GH180 versions prior to V8.0 through V8.3.3, which stems from improper access control of the maintenance connection a...

6.1CVSS6.8AI score0.00118EPSS
Exploits0References3
NVD
NVD
added 2023/05/24 9:15 p.m.8 views

CVE-2023-31458

A vulnerability in the Edge Gateway component of Mitel MiVoice Connect versions 19.3 SP2 22.24.1500.0 and earlier could allow an unauthenticated attacker with internal network access to authenticate with administrative privileges, because initial installation does not enforce a password change. A...

9.8CVSS9.7AI score0.00828EPSS
Exploits0References2
Prion
Prion
added 2023/05/24 8:15 p.m.11 views

Command injection

A vulnerability in the Connect Mobility Router component of Mitel MiVoice Connect versions 9.6.2208.101 and earlier could allow an unauthenticated attacker with internal network access to authenticate with administrative privileges, because the initial installation does not enforce a password...

5.8CVSS8.8AI score0.00121EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2023/05/24 12:0 a.m.56 views

CVE-2023-31458

Summary of CVE-2023-31458 (Mitel MiVoice Connect Edge Gateway) : The Edge Gateway component in MiVoice Connect versions 19.3 SP2 (22.24.1500.0) and earlier allows an unauthenticated attacker with internal network access to authenticate with administrative privileges because the initial installati...

9.8CVSS9.5AI score0.00828EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2023/05/24 12:0 a.m.55 views

CVE-2023-31459

CVE-2023-31459 affects Mitel MiVoice Connect’s Connect Mobility Router component, in versions 9.6.2208.101 and earlier. The root cause is that initial installation does not enforce a password change, allowing an unauthenticated attacker with internal network access to authenticate with administra...

8.8CVSS8.8AI score0.00121EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2023/05/24 12:0 a.m.10 views

CVE-2023-31459

A vulnerability in the Connect Mobility Router component of Mitel MiVoice Connect versions 9.6.2208.101 and earlier could allow an unauthenticated attacker with internal network access to authenticate with administrative privileges, because the initial installation does not enforce a password...

9.1AI score0.00121EPSS
Exploits0References2
CNVD
CNVD
added 2018/03/08 12:0 a.m.2 views

Polycom QDX 6000 Cross-Site Request Forgery Vulnerability

Polycom QDX 6000 devices is a video conferencing endpoint device from Polycom, Inc.Web application interface is one of the Web application interfaces. A cross-site request forgery vulnerability exists in the web application interface in Polycom QDX 6000 devices. A remote attacker could use this...

8.8CVSS7AI score0.00149EPSS
Exploits0References1
CERT
CERT
added 2008/03/06 12:0 a.m.23 views

AirSpan WiMAX ProST web management interface authentication bypass vulnerability

Overview The AirSpan WiMAX ProST contains an authentication bypass vulnerability that could allow an unauthenticated, remote attacker to make arbitrary configuration changes. Description The AirSpan WiMAX ProST is customer premise equipment that provides WiMAX wireless networking. The web...

10CVSS6.7AI score0.37379EPSS
Exploits1References8
Rows per page
Query Builder