Rockwell Automation Kinetix 6200, 460Vac, AM, 34.6A, S0 Drive 2094-SE02F-M00S0/2094-BM05-M
Binary data 753935.prm...
Rockwell Automation Kinetix 6000, 460VAC, AM, 30A/45A 2094-BM03
Binary data 753906.prm...
Rockwell Automation Kinetix 6000, 460VAC, AM, 49A/79A 2094-BM05
Binary data 753907.prm...
Crestron AMBarco wePresent WiPGExtron ShareLinkTeq AV ITSHARP PN-L703WAOptoma WPS-ProBlackbox HD WPSInFocus LiteShow - Remote Command Injection
Crestron AMBarco wePresent WiPGExtron ShareLinkTeq AV ITSHARP PN-L703WAOptoma WPS-ProBlackbox HD WPSInFocus LiteShow - Remote Command Injection Exploit Title: Barco/AWIND OEM Presentation Platform Unauthenticated Remote Command Injection Date: 05/01/2019 Exploit Author: Jacob Baines Tested on:...
Barco/AWIND OEM Presentation Platform Unauthenticated Remote Command Injection
Exploit Title: Barco/AWIND OEM Presentation Platform Unauthenticated Remote Command Injection Date: 05/01/2019 Exploit Author: Jacob Baines Tested on: Crestron AM-100 1.6.0.2 CVE : CVE-2019-3929 PoC Video: https://www.youtube.com/watch?v=q-PIjnPcu2k Advisory:...
Barco / AWIND OEM Presentation Platform Unauthenticated Remote Command Injection Vulnerability
Exploit for hardware platform in category web applications Exploit Title: Barco/AWIND OEM Presentation Platform Unauthenticated Remote Command Injection Exploit Author: Jacob Baines Tested on: Crestron AM-100 1.6.0.2 CVE : CVE-2019-3929 PoC Video: https://www.youtube.com/watch?v=q-PIjnPcu2k...
CVE-2019-3936
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an acti...
CVE-2019-3938
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any...
CVE-2019-3938
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any...
CVE-2019-3937
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data...
CVE-2019-3939
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device...
CVE-2019-3935
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows...
CVE-2019-3934
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code...
CVE-2019-3935
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows...
CVE-2019-3925
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root...
Design/Logic Flaw
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter...
CVE-2019-3931
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root...
Command injection
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pr...
Code injection
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows...
Command injection
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root...