Lucene search
K

6 matches found

EUVD
EUVD
added 2026/06/03 12:30 a.m.10 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.0016EPSS
Exploits0References3
Cvelist
Cvelist
added 2026/06/02 9:6 p.m.31 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.0016EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2026/06/02 2:0 p.m.6 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References4
CVE
CVE
added 2026/06/02 2:0 p.m.14 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 monitors running VG4.1.1, VG4.0.3, and lower are affected by network message handling vulnerabilities. The issue allows network-adjacent attackers to spoof or tamper with data and to cause denial-of-service conditions. If an attacker ...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References2
EUVD
EUVD
added 2026/06/02 2:0 p.m.10 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2026/06/02 12:0 a.m.8 views

PT-2026-45739

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References3
Rows per page
Query Builder