Lucene search
+L

9 matches found

OSV
OSV
•added 2026/01/14 4:15 p.m.•14 views

CVE-2025-67399

An issue in AIRTH SMART HOME AQI MONITOR Bootloader v.1.005 allows a physically proximate attacker to obtain sensitive information via the UART port of the BK7231N controller Wi-Fi and BLE module on the device is open to access...

4.6CVSS5.8AI score0.00171EPSS
SaveExploits0References2
EUVD
EUVD
•added 2025/10/03 8:07 p.m.•23 views

EUVD-2024-48334

Malicious code in bioql PyPI...

8.6CVSS6.6AI score0.00255EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/05/30 12:00 a.m.•14 views

jct-aq Airpointer 2D 安全漏洞

The jct-aq Airpointer 2D is a device for air quality monitoring from the Austrian company jct-aq. A security vulnerability exists in the jct-aq Airpointer 2D that stems from an improperly assigned privilege, which could result in elevated privileges to the root user...

7.8CVSS6.6AI score0.00158EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/08/12 12:00 a.m.•5 views

CVE-2024-7408: Cleartext Transmission of Sensitive Information

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this...

8.6CVSS5.8AI score0.00255EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2024/08/09 10:40 a.m.•41 views

CVE-2024-7408 Information Disclosure Vulnerability in Airveda Air Quality Monitor

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this...

8.6CVSS0.00255EPSS
SaveExploits0References1
CVE
CVE
•added 2024/08/09 10:40 a.m.•90 views

CVE-2024-7408

CVE-2024-7408 affects Airveda Air Quality Monitor PM2.5/PM10. The issue is information disclosure through plaintext transmission in the AP pairing mode, enabling an attacker in proximity to capture Wi‑Fi traffic. This can facilitate an Evil Twin attack on the targeted system. The CVSS metrics ind...

8.6CVSS6AI score0.00255EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2024/08/09 10:40 a.m.•23 views

CVE-2024-7408 Information Disclosure Vulnerability in Airveda Air Quality Monitor

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this...

8.6CVSS6.6AI score0.00255EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2024/08/09 12:00 a.m.•4 views

PT-2024-38325

Name of the Vulnerable Software and Affected Versions Airveda Air Quality Monitor PM2.5 PM10 affected versions not specified Description This issue exists due to the transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this by...

8.6CVSS5.7AI score0.00255EPSS
SaveExploits0References6
CNVD
CNVD
•added 2017/11/28 12:00 a.m.•6 views

Xiaofeng Air Ching App for Android suffers from arbitrary account password reset vulnerability

Xiaofeng Air Dorje APP is the APP developed by Shenzhen Xiaofeng Technology Co., Ltd. to work with Xiaofeng Air Dorje system, mainly used to monitor the indoor air quality and Xiaofeng Air Dorje internal and external machine operation status, monitoring items including PM2.5, formaldehyde, oxygen...

7.2AI score
SaveExploits0
Rows per page
Query Builder