Lucene search
+L

2796 matches found

CVE
CVE
added 2025/11/19 12:00 a.m.25 views

CVE-2025-63207

The CVE-2025-63207 affects R.V.R Elettronica TEX: firmware TEXL-000400 and Web GUI TLAN-000400. It describes a broken access control flaw due to improper authentication checks on the /_Passwd.html endpoint, allowing an unauthenticated POST that can change Admin, Operator, and User passwords and p...

9.8CVSS6.9AI score0.0697EPSS
SaveExploits1References2Affected Software1
RedhatCVE
RedhatCVE
added 2025/11/17 6:04 a.m.20 views

CVE-2016-15056

Ubee EVW3226 cable modem/routers firmware versions up to and including 1.0.20 store configuration backup files in the web root after they are generated for download. These backup files remain accessible without authentication until the next reboot. A remote attacker on the local network can reque...

8.7CVSS6.5AI score0.00626EPSS
SaveExploits0References1
NVD
NVD
added 2025/11/14 11:15 p.m.21 views

CVE-2016-15056

Ubee EVW3226 cable modem/routers firmware versions up to and including 1.0.20 store configuration backup files in the web root after they are generated for download. These backup files remain accessible without authentication until the next reboot. A remote attacker on the local network can reque...

8.7CVSS0.00626EPSS
SaveExploits0References5
Cvelist
Cvelist
added 2025/11/14 10:49 p.m.26 views

CVE-2016-15056 Ubee EVW3226 Unauthenticated Backup File Disclosure

Ubee EVW3226 cable modem/routers firmware versions up to and including 1.0.20 store configuration backup files in the web root after they are generated for download. These backup files remain accessible without authentication until the next reboot. A remote attacker on the local network can reque...

8.7CVSS0.00626EPSS
SaveExploits0References5
EUVD
EUVD
added 2025/11/14 10:49 p.m.11 views

EUVD-2016-10800

Ubee EVW3226 cable modem/routers firmware versions up to and including 1.0.20 store configuration backup files in the web root after they are generated for download. These backup files remain accessible without authentication until the next reboot. A remote attacker on the local network can reque...

8.7CVSS6.1AI score0.00626EPSS
SaveExploits0References6
Vulnrichment
Vulnrichment
added 2025/11/14 10:49 p.m.11 views

CVE-2016-15056 Ubee EVW3226 Unauthenticated Backup File Disclosure

Ubee EVW3226 cable modem/routers firmware versions up to and including 1.0.20 store configuration backup files in the web root after they are generated for download. These backup files remain accessible without authentication until the next reboot. A remote attacker on the local network can reque...

8.7CVSS6.2AI score0.00626EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2025/11/14 12:00 a.m.20 views

PT-2025-47014

Name of the Vulnerable Software and Affected Versions Ubee EVW3226 versions up to and including 1.0.20 Description The Ubee EVW3226 cable modem/router firmware stores configuration backup files in the web root after they are generated for download. These files remain accessible without...

8.7CVSS6.3AI score0.00626EPSS
SaveExploits0References7
Tenable Nessus
Tenable Nessus
added 2025/11/13 12:00 a.m.7 views

Generex UPS Adapter CS141 Improper Input Validation (CVE-2022-47192)

Generex UPS CS141 below 2.06 version, could allow a remote attacker to upload a backup file containing a modified users.json to the web server of the device, allowing him to replace the administrator password. This plugin only works with Tenable.ot. Please visit...

8.8CVSS8.4AI score0.01301EPSS
SaveExploits0References4
RedhatCVE
RedhatCVE
added 2025/11/07 1:46 p.m.11 views

CVE-2025-59396

The default configuration of WatchGuard Firebox devices through 2025-09-10 allows administrative access via SSH on port 4118 with the readwrite password for the admin account...

9.8CVSS7.1AI score0.00043EPSS
SaveExploits3References1
EUVD
EUVD
added 2025/11/06 6:32 p.m.13 views

EUVD-2025-38053

The default configuration of WatchGuard Firebox devices through 2025-09-10 allows administrative access via SSH on port 4118 with the readwrite password for the admin account...

6.5AI score0.00043EPSS
SaveExploits3References3
EUVD
EUVD
added 2025/11/06 6:32 p.m.8 views

EUVD-2025-38049

On Elspec G5 devices through 1.2.2.19, a person with physical access to the device can reset the Admin password by inserting a USB drive containing a publicly documented reset string into a USB port...

6.8CVSS6.2AI score0.00211EPSS
SaveExploits0References3
OSV
OSV
added 2025/11/06 4:16 p.m.9 views

CVE-2025-59392

On Elspec G5 devices through 1.2.2.19, a person with physical access to the device can reset the Admin password by inserting a USB drive containing a publicly documented reset string into a USB port...

6.8CVSS5.8AI score0.00211EPSS
SaveExploits0References2
NVD
NVD
added 2025/11/06 4:16 p.m.8 views

CVE-2025-59392

On Elspec G5 devices through 1.2.2.19, a person with physical access to the device can reset the Admin password by inserting a USB drive containing a publicly documented reset string into a USB port...

6.8CVSS0.00211EPSS
SaveExploits0References2
CVE
CVE
added 2025/11/06 12:00 a.m.24 views

CVE-2025-59392

The CVE describes a vulnerability in Elspec G5 devices (versions up to and including 1.2.2.19) where a user with physical access can reset the Admin password by inserting a USB drive containing a publicly documented reset string. Root cause is physical access combined with USB-based reset data; i...

6.8CVSS6.3AI score0.00211EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
added 2025/11/06 12:00 a.m.10 views

PT-2025-45340

Name of the Vulnerable Software and Affected Versions WatchGuard Firebox versions through 2025-09-10 Description The default configuration of WatchGuard Firebox devices allows administrative access via SSH on port 4118 using the default 'readwrite' password for the 'admin' account. This allows...

9.8CVSS7.3AI score0.00043EPSS
SaveExploits3References12
Cvelist
Cvelist
added 2025/11/06 12:00 a.m.12 views

CVE-2025-59392

On Elspec G5 devices through 1.2.2.19, a person with physical access to the device can reset the Admin password by inserting a USB drive containing a publicly documented reset string into a USB port...

0.00211EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/11/06 12:00 a.m.4 views

CVE-2025-59392

On Elspec G5 devices through 1.2.2.19, a person with physical access to the device can reset the Admin password by inserting a USB drive containing a publicly documented reset string into a USB port...

6.3AI score0.00211EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2025/11/06 12:00 a.m.13 views

PT-2025-45256

Name of the Vulnerable Software and Affected Versions Elspec G5 versions through 1.2.2.19 Description A person with physical access to the device can reset the Admin password by inserting a USB drive containing a publicly documented reset string into a USB port. Recommendations Versions prior to...

6.8CVSS8AI score0.00211EPSS
SaveExploits0References4
Packet Storm
Packet Storm
added 2025/11/03 12:00 a.m.123 views

📄 Ilevia EVE X1/X5 Server 4.7.18.0.eden Default Credentials

Ilevia EVE X1/X5 Server version 4.7.18.0.eden uses a weak set of default administrative credentials that can be found and used to gain full control of the system. Ilevia EVE X1/X5 Server 4.7.18.0.eden Default Credentials Vendor: Ilevia Srl. Product web page: https://www.ilevia.com Affected versio...

9.8CVSS7.2AI score0.00545EPSS
SaveExploits2
CNVD
CNVD
added 2025/10/31 12:00 a.m.26 views

IPFire Cross-Site Scripting Vulnerability (CNVD-2025-27644)

IPFire is an open source Linux distribution from the IPFire organization. It is mainly used as a router and firewall. IPFire suffers from a cross-site scripting vulnerability that stems from insufficient cleanup and escaping of the TLSHOSTNAME, UPSTREAMUSER, UPSTREAMPASSWORD, ADMINMAILADDRESS, an...

5.1CVSS6.1AI score0.00479EPSS
SaveExploits0References1
Rows per page
Query Builder