PT-2019-1502
Name of the Vulnerable Software and Affected Versions Cisco Firepower 9000 Series version 2.2 Description A logic error in the field-programmable gate array FPGA related to the processing of different types of input packets could allow an unauthenticated, adjacent attacker to cause a denial of...
CVE-2018-15380: Improper Neutralization of Special Elements used in an OS Command
A vulnerability in the cluster service manager of Cisco HyperFlex Software could allow an unauthenticated, adjacent attacker to execute commands as the root user. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by connecting to the cluster...
PT-2019-1531
Name of the Vulnerable Software and Affected Versions Cisco HyperFlex Software versions prior to 3.52a Description A vulnerability in the cluster service manager of Cisco HyperFlex Software could allow an unauthenticated, adjacent attacker to execute commands as the root user. The issue is due to...
MariaDB 5.5.0 < 5.5.62 Multiple Vulnerabilities
The version of MariaDB installed on the remote host is prior to 5.5.62. It is, therefore, affected by multiple vulnerabilities as referenced in the 5.5.62 advisory. - The crc32big function in crc32.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact via vectors...
Authentication flaw
A vulnerability in the Cisco SD-WAN Solution could allow an authenticated, adjacent attacker to bypass authentication and have direct unauthorized access to other vSmart containers. The vulnerability is due to an insecure default configuration of the affected system. An attacker could exploit thi...
Input validation
A vulnerability in the Cisco Connected Mobile Experiences CMX software could allow an unauthenticated, adjacent attacker to access sensitive data on an affected device. The vulnerability is due to a lack of input and validation checking mechanisms for certain GET requests to API's on an affected...
CVE-2019-1645: Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability in the Cisco Connected Mobile Experiences CMX software could allow an unauthenticated, adjacent attacker to access sensitive data on an affected device. The vulnerability is due to a lack of input and validation checking mechanisms for certain GET requests to API's on an affected...
Cisco Connected Mobile Experiences Information Disclosure Vulnerability
A vulnerability in the Cisco Connected Mobile Experiences CMX software could allow an unauthenticated, adjacent attacker to access sensitive data on an affected device. The vulnerability is due to a lack of input and validation checking mechanisms for certain GET requests to API's on an affected...
PT-2019-1387
Name of the Vulnerable Software and Affected Versions Cisco Connected Mobile Experiences CMX affected versions not specified Description A vulnerability in the Cisco Connected Mobile Experiences CMX software could allow an unauthenticated, adjacent attacker to access sensitive data on an affected...
ABB M2M ETHERNET
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Exploitable from an adjacent network/low skill level to exploit Vendor: ABB Equipment: M2M ETHERNET Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to upload a malicious...
CVE-2018-18562
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service interface...
CVE-2018-18564
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 Serial number above KQ0400000 or KS0400000. Improper access control allow...
CVE-2018-18565
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...
Design/Logic Flaw
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...
CVE-2018-18564
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 Serial number above KQ0400000 or KS0400000. Improper access control allow...
CVE-2018-18565
CVE-2018-18565 is an Improper Access Control (CWE-284) vulnerability in Roche Diagnostics handheld medical devices (Accu-Chek Inform II Instrument and related models) where attackers in the adjacent network can change instrument configuration. Affected products include Accu-Chek Inform II Instrum...
CVE-2018-18561
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute arbitrary commands on the...
CVE-2018-18565
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...
CVE-2018-18564
CVE-2018-18564 affects Roche Diagnostics handheld medical devices (Accu-Chek Inform II Instrument, CoaguChek Pro II, cobas h 232) with improper access control that allows attackers in the adjacent network to change instrument configuration. The related ICS-CERT Update A documents additional conte...
PT-2018-14518
Name of the Vulnerable Software and Affected Versions Roche Accu-Chek Inform II Instrument versions prior to 03.06.00 Serial number below 14000 Roche Accu-Chek Inform II Instrument versions 04.x prior to 04.03.00 Serial Number above 14000 CoaguChek Pro II versions prior to 04.03.00 cobas h 232...