3479 matches found
CVE-2019-1746 Cisco IOS and IOS XE Software Cluster Management Protocol Denial of Service Vulnerability
A vulnerability in the Cluster Management Protocol CMP processing code in Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, adjacent attacker to trigger a denial of service DoS condition on an affected device. The vulnerability is due to insufficient input validation wh...
CVE-2019-6540
The CVE-2019-6540 issue is concrete: the Conexus telemetry protocol used by Medtronic MyCareLink/CareLink devices and related CRT-D/ICD hardware does not encrypt communications (Cleartext Transmission of Sensitive Information) and, per ICS-CERT, can be exploited by an attacker with adjacent, shor...
CVE-2019-6538
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro IC...
(0Day) (Pwn2Own) Xiaomi Mi6 Captive Portal Whitelist Bypass Remote Code Execution Vulnerability
This vulnerability allows network adjacent attackers to execute arbitrary code on vulnerable installations of Xiaomi Mi6. User interaction is required to exploit this vulnerability in that the target must connect to a malicious access point. The specific flaw exists within the handling of...
CVE-2019-1617
Cisco NX-OS Software on Nexus 9000 Series Switches in Standalone NX-OS Mode is affected by CVE-2019-1617. The issue stems from incorrect processing of FCoE packets when the fcoe-npv feature is uninstalled, enabling an unauthenticated adjacent attacker to cause a denial of service by sending a str...
CVE-2019-1690
A vulnerability in the management interface of Cisco Application Policy Infrastructure Controller APIC software could allow an unauthenticated, adjacent attacker to gain unauthorized access on an affected device. The vulnerability is due to a lack of proper access control mechanisms for IPv6...
Race condition
A vulnerability in the Cisco Discovery Protocol or Link Layer Discovery Protocol LLDP implementation for the Cisco IP Phone 7800 and 8800 Series could allow an unauthenticated, adjacent attacker to cause an affected phone to reload unexpectedly, resulting in a temporary denial of service DoS...
CVE-2019-1684 Cisco IP Phone 7800 and 8800 Series Cisco Discovery Protocol and Link Layer Discovery Protocol Denial of Service Vulnerability
A vulnerability in the Cisco Discovery Protocol or Link Layer Discovery Protocol LLDP implementation for the Cisco IP Phone 7800 and 8800 Series could allow an unauthenticated, adjacent attacker to cause an affected phone to reload unexpectedly, resulting in a temporary denial of service DoS...
CVE-2018-15380 Cisco HyperFlex Software Command Injection Vulnerability
A vulnerability in the cluster service manager of Cisco HyperFlex Software could allow an unauthenticated, adjacent attacker to execute commands as the root user. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by connecting to the cluster...
MariaDB 5.5.0 < 5.5.62 Multiple Vulnerabilities
The version of MariaDB installed on the remote host is prior to 5.5.62. It is, therefore, affected by multiple vulnerabilities as referenced in the 5.5.62 advisory. - The crc32big function in crc32.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact via vectors...
Input validation
A vulnerability in the Cisco Connected Mobile Experiences CMX software could allow an unauthenticated, adjacent attacker to access sensitive data on an affected device. The vulnerability is due to a lack of input and validation checking mechanisms for certain GET requests to API's on an affected...
Authentication flaw
A vulnerability in the Cisco SD-WAN Solution could allow an authenticated, adjacent attacker to bypass authentication and have direct unauthorized access to other vSmart containers. The vulnerability is due to an insecure default configuration of the affected system. An attacker could exploit thi...
Cisco Connected Mobile Experiences Information Disclosure Vulnerability
A vulnerability in the Cisco Connected Mobile Experiences CMX software could allow an unauthenticated, adjacent attacker to access sensitive data on an affected device. The vulnerability is due to a lack of input and validation checking mechanisms for certain GET requests to API's on an affected...
ABB M2M ETHERNET
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Exploitable from an adjacent network/low skill level to exploit Vendor: ABB Equipment: M2M ETHERNET Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to upload a malicious...
CVE-2018-18564
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 Serial number above KQ0400000 or KS0400000. Improper access control allow...
CVE-2018-18562
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service interface...
CVE-2018-18564
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 Serial number above KQ0400000 or KS0400000. Improper access control allow...
CVE-2018-18565
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...
Design/Logic Flaw
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...
CVE-2018-18564
CVE-2018-18564 affects Roche Diagnostics handheld medical devices (Accu-Chek Inform II Instrument, CoaguChek Pro II, cobas h 232) with improper access control that allows attackers in the adjacent network to change instrument configuration. The related ICS-CERT Update A documents additional conte...