Lucene search
+L

676 matches found

NVD
NVD
added 2020/02/10 4:15 p.m.19 views

CVE-2012-1994

HP Systems Insight Manager before 7.0 allows a remote user on adjacent network to access information...

5.7CVSS5.5AI score0.00793EPSS
SaveExploits0References3
NVD
NVD
added 2019/09/06 10:15 p.m.22 views

CVE-2019-9461

In the Android kernel in VPN routing there is a possible information disclosure. This could lead to remote information disclosure by an adjacent network attacker with no additional execution privileges needed. User interaction is not needed for exploitation...

6.5CVSS6.4AI score0.015EPSS
SaveExploits1References4
CNVD
CNVD
added 2019/05/22 12:0 a.m.6 views

Intel AMT Subsystem Input Validation Error Vulnerability (CNVD-2019-27317)

Intel Active Management Technology AMT is a set of hardware-based computer remote active management technology software from Intel Intel. An input validation error vulnerability exists in a subsystem in Intel AMT. The vulnerability originates from a network system or product that does not properl...

4.3CVSS6.8AI score0.00451EPSS
SaveExploits0References1
NVD
NVD
added 2019/05/17 4:29 p.m.24 views

CVE-2019-0094

Insufficient input validation vulnerability in subsystem for IntelR AMT before versions 11.8.65, 11.11.65, 11.22.65, 12.0.35 may allow an unauthenticated user to potentially enable denial of service via adjacent network access...

4.3CVSS4.6AI score0.00451EPSS
SaveExploits0References2
OSV
OSV
added 2019/05/17 4:29 p.m.5 views

CVE-2019-0096

Out of bound write vulnerability in subsystem for IntelR AMT before versions 11.8.65, 11.11.65, 11.22.65, 12.0.35 may allow an authenticated user to potentially enable escalation of privilege via adjacent network access...

8CVSS5.8AI score0.00495EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2019/05/17 3:41 p.m.34 views

CVE-2019-0096

Out of bound write vulnerability in subsystem for IntelR AMT before versions 11.8.65, 11.11.65, 11.22.65, 12.0.35 may allow an authenticated user to potentially enable escalation of privilege via adjacent network access...

8AI score0.00495EPSS
SaveExploits0References2
ICS
ICS
added 2018/12/18 12:0 a.m.85 views

ABB M2M ETHERNET

1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Exploitable from an adjacent network/low skill level to exploit Vendor: ABB Equipment: M2M ETHERNET Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to upload a malicious...

4.3CVSS5AI score0.00787EPSS
SaveExploits0References5
OSV
OSV
added 2018/11/20 7:29 p.m.8 views

CVE-2018-18564

An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 Serial number above KQ0400000 or KS0400000. Improper access control allow...

7.4CVSS5.8AI score0.00584EPSS
SaveExploits0References2
OSV
OSV
added 2018/11/20 7:29 p.m.10 views

CVE-2018-18565

An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...

6.8CVSS5.9AI score0.00475EPSS
SaveExploits0References2
OSV
OSV
added 2018/11/20 7:29 p.m.9 views

CVE-2018-18562

An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service interface...

8.8CVSS5.8AI score0.00715EPSS
SaveExploits0References2
Prion
Prion
added 2018/11/20 7:29 p.m.21 views

Design/Logic Flaw

An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...

4.1CVSS7.1AI score0.00475EPSS
SaveExploits0References2Affected Software5
NVD
NVD
added 2018/11/20 7:29 p.m.20 views

CVE-2018-18564

An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 Serial number above KQ0400000 or KS0400000. Improper access control allow...

7.4CVSS7.8AI score0.00584EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/11/20 7:0 p.m.24 views

CVE-2018-18565

An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 Serial number below 14000 and 04.x before 04.03.00 Serial Number above 14000, CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 Serial...

6.5AI score0.00475EPSS
SaveExploits0References2
CVE
CVE
added 2018/11/20 7:0 p.m.54 views

CVE-2018-18564

CVE-2018-18564 affects Roche Diagnostics handheld medical devices (Accu-Chek Inform II Instrument, CoaguChek Pro II, cobas h 232) with improper access control that allows attackers in the adjacent network to change instrument configuration. The related ICS-CERT Update A documents additional conte...

7.4CVSS7.3AI score0.00584EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2018/11/20 7:0 p.m.29 views

CVE-2018-18561

An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute arbitrary commands on the...

8.1AI score0.00671EPSS
SaveExploits0References2
CVE
CVE
added 2018/11/20 7:0 p.m.52 views

CVE-2018-18565

CVE-2018-18565 is an Improper Access Control (CWE-284) vulnerability in Roche Diagnostics handheld medical devices (Accu-Chek Inform II Instrument and related models) where attackers in the adjacent network can change instrument configuration. Affected products include Accu-Chek Inform II Instrum...

6.8CVSS6.5AI score0.00475EPSS
SaveExploits0References2Affected Software1
Tenable Nessus
Tenable Nessus
added 2018/11/02 12:0 a.m.29 views

F5 Networks BIG-IP : TMM vulnerability (K37404773)

An undisclosed sequence of packets, sourced from an adjacent network may cause TMM to crash.CVE-2017-6134 Impact This issue is exposed in the default configuration. Traffic processing is disrupted while the Traffic Management Microkernel TMM restarts. If the affected F5 device is configured as pa...

6.5CVSS6.5AI score0.00866EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2018/11/02 12:0 a.m.24 views

F5 Networks BIG-IP : vCMP vulnerability (K64721111)

Through undisclosed methods,adjacent network attackers can cause a denial of service for vCMP guest and host systems. Attacks must be sourced from an adjacent network Layer 2. CVE-2018-5531 Impact BIG-IP An attacker from an adjacent network may be able to cause a denial-of-service DoS attack on t...

7.4CVSS7.3AI score0.00507EPSS
SaveExploits0References2
NVD
NVD
added 2018/10/23 9:30 p.m.16 views

CVE-2018-17873

An incorrect access control vulnerability in the FTP configuration of WiFiRanger devices with firmware version 7.0.8rc3 and earlier allows an attacker with adjacent network access to read the SSH Private Key and log in to the root account...

8.8CVSS8.6AI score0.01853EPSS
SaveExploits3References1
Prion
Prion
added 2018/10/23 9:30 p.m.18 views

Improper access control

An incorrect access control vulnerability in the FTP configuration of WiFiRanger devices with firmware version 7.0.8rc3 and earlier allows an attacker with adjacent network access to read the SSH Private Key and log in to the root account...

3.3CVSS8.4AI score0.01853EPSS
SaveExploits3References1Affected Software1
Rows per page
Query Builder