25 matches found
EUVD-2023-35485
Malicious code in bioql PyPI...
CVE-2023-31171
An Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See...
CVE-2023-31168
An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and...
CVE-2023-31172 Incomplete Filtering of Special Elements
An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...
CVE-2023-31172
The CVE-2023-31172 issue affects Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software up to version 7.1.3.0. The vulnerability stems from incomplete filtering of certain elements, which could permit an attacker to embed commands that could be executed by an authorized device...
CVE-2023-31171 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
An Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See...
CVE-2023-31171
CVE-2023-31171 affects SEL-5030 acSELerator QuickSet Software up to 7.1.3.0. Root cause: Improper Neutralization of Special Elements in SQL commands (SQL injection) that could allow an attacker to cause arbitrary code execution on the engineering workstation. Exploitation vector described in conn...
CVE-2023-31170
SEL-5030 acSELerator QuickSet Software is affected up to version 7.1.3.0 by CVE-2023-31170, described as an Inclusion of Functionality from Untrusted Control Sphere issue. The vulnerability could allow an attacker to embed instructions that could be executed by an authorized device operator. Conn...
CVE-2023-31169 Improper Handling of Unicode Encoding
An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...
CVE-2023-31168
The CVE-2023-31168 issue affects Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software up to version 7.1.3.0. Root cause: Inclusion of Functionality from Untrusted Control Sphere, enabling an attacker to embed instructions that could be executed by an authorized device operat...
CVE-2023-31168 Inclusion of Functionality from Untrusted Control Sphere
An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and...
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet 安全漏洞
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software is a Schweitzer Engineering Laboratories, Inc. tool for configuring, commissioning and managing power system protection, control, metering and monitoring equipment. monitoring equipment of the power system. A security...
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet 安全漏洞
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software is a Schweitzer Engineering Laboratories, Inc. tool for configuring, commissioning and managing power system protection, control, metering and monitoring equipment. monitoring equipment of the power system. A security...
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet 安全漏洞
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software is a Schweitzer Engineering Laboratories, Inc. tool for configuring, commissioning and managing power system protection, control, metering and monitoring equipment. monitoring equipment of the power system. A security...
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet SQL注入漏洞
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software is a Schweitzer Engineering Laboratories, Inc. tool for configuring, commissioning and managing power system protection, control, metering and monitoring equipment. monitoring equipment of the power system. A security...
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet 安全漏洞
Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software is a Schweitzer Engineering Laboratories, Inc. tool for configuring, commissioning and managing power system protection, control, metering and monitoring equipment. monitoring equipment of the power system. A security...
PT-2023-5213 · Schweitzer Engineering Laboratories · Acselerator Quickset
Name of the Vulnerable Software and Affected Versions: Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software versions through 7.1.3.0 Description: The issue is related to an improper handling of Unicode encoding, which could allow an attacker to embed instructions that could ...
PT-2023-5476 · Schweitzer Engineering Laboratories · Acselerator Quickset
Name of the Vulnerable Software and Affected Versions: Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software versions through 7.1.3.0 Description: The issue is related to an Incomplete Filtering of Special Elements, which could allow an attacker to embed instructions that cou...
PT-2023-5477 · Schweitzer Engineering Laboratories · Acselerator Quickset
Name of the Vulnerable Software and Affected Versions: Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software versions through 7.1.3.0 Description: The issue is related to an Inclusion of Functionality from Untrusted Control Sphere vulnerability, which could allow an attacker ...
SEL (CVE-2013-0665) (deprecated)
Plugin deprecated because acselerator is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable- ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. @DEPRECATED@ Disabled on 2023/03/10. Deprecated because...