420 matches found
The vulnerability of function R7WebsSecurityHandler (/goform/execCommand) in the Tenda AC8 router’s microprogramming system, which allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.
The vulnerability of function R7WebsSecurityHandler /goform/execCommand in the Tenda AC8 router’s microprogramming system is related to buffer overflow in the stack. Exploiting this vulnerability could allow an attacker to compromise the confidentiality, integrity, and accessibility of the...
The vulnerability of the fromAdvSetMacMtuWan function (/goform/AdvSetMacMtuWan) in the Tenda AC8 router software allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.
The vulnerability of the fromAdvSetMacMtuWan function /goform/AdvSetMacMtuWan of the Tenda AC8 router software is related to buffer overflow in the stack. Exploiting this vulnerability can allow an attacker to compromise the confidentiality, integrity, and accessibility of protected information b...
Stack buffer overflow vulnerability in Tenda AC8 formSetRebootTimer function
The Tenda AC8 is a router product that is primarily used for network connectivity in homes and small offices. Tenda AC8 has a stack buffer overflow vulnerability in the formSetRebootTimer function of the /goform/SetRebootTimer file in version 16.03.34.09. An attacker can use this vulnerability to...
Tenda AC8 fromAdvSetMacMtuWan function has a stack buffer overflow vulnerability
The Tenda AC8 is a router device that provides network connectivity and data transfer capabilities. A security vulnerability exists in Tenda AC8 version 16.03.34.09, which originates from a buffer overflow vulnerability in the function fromAdvSetMacMtuWan in file /goform/AdvSetMacMtuWan. No detai...
CVE-2024-4066
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...
CVE-2024-4066
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...
CVE-2024-4066 Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...
CVE-2024-4066
CVE-2024-4066 affects Tenda AC8 firmware 16.03.34.09. The vulnerability exists in function fromAdvSetMacMtuWan (file /goform/AdvSetMacMtuWan) where manipulating arguments wanMTU/wanSpeed/cloneType/mac/serviceName/serverName triggers a stack-based buffer overflow. It is exploitable remotely and pu...
CVE-2024-4066 Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...
CVE-2024-4065
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-4065
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-4064
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-4065 Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-4065 Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-4065
The CVE-2024-4065 entry concerns the Tenda AC8 firmware (16.03.34.09) with a stack-based buffer overflow in the formSetRebootTimer function exposed via /goform/SetRebootTimer. The rebootTime parameter manipulation can be exploited remotely to run arbitrary code. Multiple sources confirm remote at...
CVE-2024-4064 Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-4064
CVE-2024-4064 affects Tenda AC8 16.03.34.09. The R7WebsSecurityHandler function in /goform/execCommand mishandles the password parameter, causing a stack-based buffer overflow. This enables remote exploitation; the exploit has been disclosed publicly. Multiple sources (NVD, Red Hat, CNVD, CNNVD, ...
CVE-2024-4064 Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...
Tenda AC8 安全漏洞
The Tenda AC8 is a router product that is primarily used for network connectivity in homes and small offices. Tenda AC8 has a stack buffer overflow vulnerability in the formSetRebootTimer function of the /goform/SetRebootTimer file in version 16.03.34.09. An attacker can use this vulnerability to...
Tenda AC8 安全漏洞
Shenzhen Jixiang Tengda Technology Co., Ltd AC8 is a wireless router device that provides network connection and wireless management functions. A stack buffer overflow vulnerability exists in the R7WebsSecurityHandler function in the Shenzhen Jixiang Tengda Technology Co. AC8 /goform/execCommand...