Lucene search
+L

289 matches found

ATTACKERKB
ATTACKERKB
added 2023/08/30 1:15 p.m.7 views

CVE-2023-41553

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg...

9.8CVSS7.4AI score0.00701EPSS
Exploits1References2
OSV
OSV
added 2023/08/30 1:15 p.m.4 views

CVE-2023-41556

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind...

9.8CVSS5.9AI score0.00906EPSS
Exploits1References1
NVD
NVD
added 2023/08/30 1:15 p.m.14 views

CVE-2023-41553

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg...

9.8CVSS9.8AI score0.00701EPSS
Exploits1References1
OSV
OSV
added 2023/08/30 1:15 p.m.6 views

CVE-2023-41553

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg...

9.8CVSS5.9AI score0.00701EPSS
Exploits1References1
Prion
Prion
added 2023/08/30 1:15 p.m.25 views

Stack overflow

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo...

7.5CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software2
Prion
Prion
added 2023/08/30 1:15 p.m.20 views

Stack overflow

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg...

7.5CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software2
Prion
Prion
added 2023/08/30 1:15 p.m.19 views

Stack overflow

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet...

7.5CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software3
Prion
Prion
added 2023/08/30 1:15 p.m.14 views

Stack overflow

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting...

7.5CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software3
Prion
Prion
added 2023/08/30 1:15 p.m.21 views

Stack overflow

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg...

7.5CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software2
Prion
Prion
added 2023/08/30 1:15 p.m.16 views

Stack overflow

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat...

7.5CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software2
Vulnrichment
Vulnrichment
added 2023/08/30 12:0 a.m.13 views

CVE-2023-41557

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat...

7.9AI score0.00701EPSS
Exploits1References1
Cvelist
Cvelist
added 2023/08/30 12:0 a.m.32 views

CVE-2023-41557

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat...

9.9AI score0.00701EPSS
Exploits1References1
Cvelist
Cvelist
added 2023/08/30 12:0 a.m.26 views

CVE-2023-41561

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg...

9.9AI score0.00701EPSS
Exploits1References1
Cvelist
Cvelist
added 2023/08/30 12:0 a.m.26 views

CVE-2023-41563

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo...

9.9AI score0.00701EPSS
Exploits1References1
Vulnrichment
Vulnrichment
added 2023/08/30 12:0 a.m.14 views

CVE-2023-41563

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo...

7.9AI score0.00701EPSS
Exploits1References1
Vulnrichment
Vulnrichment
added 2023/08/30 12:0 a.m.12 views

CVE-2023-41561

Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg...

7.9AI score0.00701EPSS
Exploits1References1
Cvelist
Cvelist
added 2023/08/30 12:0 a.m.32 views

CVE-2023-41559

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting...

9.9AI score0.00701EPSS
Exploits1References1
Positive Technologies
Positive Technologies
added 2023/08/30 12:0 a.m.6 views

PT-2023-27975 · Tenda · Tenda Ac7 +1

Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 1.0 V15.03.06.44 Tenda AC5 version 1.0RTL V15.03.06.28 Description: A stack overflow issue was discovered via parameter entrys and mitInterface at the "/goform/addressNat" API endpoint. Recommendations: For Tenda AC7 version...

9.8CVSS9.3AI score0.00701EPSS
Exploits1References4
CVE
CVE
added 2023/08/30 12:0 a.m.43 views

CVE-2023-41557

CVE-2023-41557 affects Tenda AC7 (v1.0, v15.03.06.44) and Tenda AC5 (v1.0RTL, v15.03.06.28). A stack overflow is triggered via the entrys and mitInterface parameters at /goform/addressNat, enabling a high-severity, network-based impact with no user interaction. CVSS v3.1 indicates a critical base...

9.8CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software1
CVE
CVE
added 2023/08/30 12:0 a.m.52 views

CVE-2023-41562

CVE-2023-41562 affects Tenda routers: AC7 v1.0 (V15.03.06.44), AC9 v3.0 (V15.03.06.42_multi), and AC5 (US_AC5V1.0RTL_V15.03.06.28). The vulnerability is a stack overflow triggered by the time parameter in the /goform/PowerSaveSet API. The NVD entry assigns a CVSS v3.1 base score of 9.8 (CRITICAL)...

9.8CVSS9.7AI score0.00701EPSS
Exploits1References1Affected Software1
Rows per page
Query Builder