791 matches found
Tenda AC10 安全漏洞
The Tenda AC10 is a wireless router from the Chinese company Tenda. Tenda AC10 suffers from a command injection vulnerability that stems from a command injection vulnerability contained in the formexeCommand function, no details of the vulnerability are provided at this time...
CVE-2025-25675
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmdbuf variable, which is directly used in the doSystemCmd function, causing an arbitrary...
Tenda AC10 安全漏洞
The Tenda AC10 is a wireless router from the Chinese company Tenda. Tenda AC10 suffers from a buffer overflow vulnerability, which originates from the ssid parameter of formfastsettingwifiset contains a buffer overflow vulnerability that can be exploited by an attacker to execute arbitrary code...
CVE-2025-25674
CVE-2025-25674 affects Tenda AC10 V1.0 with firmware V15.03.06.23. Multiple connected sources (NVD/CNVD/Red Hat, CNVD, CNNVD) describe a buffer overflow in form_fast_setting_wifi_set via the ssid parameter, enabling potential arbitrary code execution on vulnerable devices. The affected component ...
PT-2025-7566 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10 V1.0 V15.03.06.23 Description: The issue is related to a buffer overflow in form fast setting wifi set via the ssid parameter. This can potentially be exploited, although specific details about the number of affected devices or...
CVE-2025-25674
Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in formfastsettingwifiset via the parameter ssid...
CVE-2025-25675
Summary: CVE-2025-25675 affects Tenda AC10 (V1.0, V15.03.06.23). The vulnerability is a command injection in the formexeCommand function. The code flow: the POST parameter cmdinput is assigned to str, then to cmd_buf, which is directly used by doSystemCmd, enabling arbitrary command execution. Mu...
PT-2025-16508 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10 version V4.0si V16.03.10.20 Description: The issue is related to a Buffer Overflow in the AdvSetMacMtuWan function via the serviceName2 variable. Recommendations: For Tenda AC10 version V4.0si V16.03.10.20, as a temporary workaroun...
PT-2025-16544 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10 version V4.0si V16.03.10.20 Description: The issue concerns a buffer overflow in the AdvSetMacMtuWan function through the serverName2 variable. This can potentially allow for unauthorized access or control. Recommendations: For Ten...
PT-2025-17048 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10 version V4.0si V16.03.10.20 Description: The issue is related to a Buffer Overflow in AdvSetMacMtuWan via cloneType2. This can potentially be exploited. No information is provided about the estimated number of affected devices or...
CVE-2025-0528
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
CVE-2024-2581
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit h...
CVE-2024-11056
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapskcrypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...
CVE-2024-11061
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN0044db3c of the file /goform/fastsettingwifiset. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The...
CVE-2024-11248
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely...
Tenda AC10 Command Injection Vulnerability
The Tenda AC10 is a wireless router from the Chinese company Tenda. A command injection vulnerability exists in Tenda AC10 version 16.03.10.20, which stems from the failure of the file /goform/telnet to properly filter constructed command special characters, commands, etc. An attacker could use...
CVE-2025-0528
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
CVE-2025-0528 Tenda AC8/AC10/AC18 HTTP Request telnet command injection
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
Tenda AC10 注入漏洞
The Tenda AC10 is a wireless router from the Chinese company Tenda. A command injection vulnerability exists in Tenda AC10 version 16.03.10.20, which stems from the failure of the file /goform/telnet to properly filter constructed command special characters, commands, etc. An attacker could use...
PT-2025-1260 · Tenda · Tenda Ac10 +2
Name of the Vulnerable Software and Affected Versions: Tenda AC8 versions 16.03.10.20 Tenda AC10 versions 16.03.10.20 Tenda AC18 versions 16.03.10.20 Description: A critical issue has been found in the HTTP Request Handler component of the affected devices, specifically in the /goform/telnet file...