13 matches found
EUVD-2025-201856
A vulnerability was determined in Tenda AC9 15.03.05.14multi. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/DownloadCfg.jpg of the component Configuration File Handler. This manipulation causes information disclosure. The attack may be initiated remotely. The...
PT-2025-39205
Name of the Vulnerable Software and Affected Versions Tenda AC9 version 1.0 Description A buffer overflow issue exists in Tenda AC9 version 1.0. The issue is related to the handling of the sys.vendor configuration value provided by the user. Recommendations At the moment, there is no information...
PT-2025-35412
Name of the Vulnerable Software and Affected Versions: Tenda AC9 version 15.03.05.19 Description: A vulnerability exists in Tenda AC9 version 15.03.05.19 related to hard-coded credentials within the Administrative Interface component. The vulnerability resides in an unknown function of the /etc...
CVE-2021-31627
Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.196318, and AC9 V3.0 V15.03.06.42multi, allows attackers to execute arbitrary code via the index parameter...
Tenda多款产品 代码问题漏洞
Tenda AC7 and others are products of Tenda, a Chinese company.Tenda AC7 is a wireless router.Tenda AC9 is a wireless router.Tenda AC10 is a wireless router. A code issue exists in a number of Tenda products where the vulnerability stems from a null pointer dereference vulnerability in the...
CVE-2023-41552
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42multi were discovered to contain a stack overflow via parameter ssid at url /goform/fastsettingwifiset...
PT-2023-27979 · Tenda · Tenda Ac9 +1
Name of the Vulnerable Software and Affected Versions: Tenda AC9 version V15.03.06.42 multi Tenda AC5 version V15.03.06.28 Description: A stack overflow issue was discovered via parameters startIp and endIp at the "/goform/SetPptpServerCfg" API endpoint. Recommendations: For Tenda AC9 version...
CVE-2022-36570
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg...
PT-2022-23478 · Tenda · Tenda Ac9
Name of the Vulnerable Software and Affected Versions: Tenda AC9 version 15.03.05.19 Description: A stack overflow issue was discovered, which can be triggered via the mask parameter at the "/goform/WanParameterSetting" API endpoint. Recommendations: For Tenda AC9 version 15.03.05.19, avoid using...
PT-2022-17283 · Tenda · Tenda Ac9
Name of the Vulnerable Software and Affected Versions: Tenda AC9 version 15.03.2.21 Description: A stack overflow issue was discovered via the schedendtime parameter in the openSchedWifi function. Recommendations: For Tenda AC9 version 15.03.2.21, consider restricting access to the openSchedWifi...
Buffer Overflow Vulnerability in Multiple Tenda Products
The Tenda AC7, among others, is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in the web server httpd in the Tenda AC7 using firmware V15.03.06.44CN AC7 and earlier, the AC9 using firmware V15.03.05.196318CN AC9 and earlier, and the AC10 using firmware...
Buffer Overflow Vulnerability in Multiple Tenda Products (CNVD-2019-13772)
The Tenda AC7, among others, is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in the web server httpd in the Tenda AC7 using firmware V15.03.06.44CN AC7 and earlier, the AC9 using firmware V15.03.05.196318CN AC9 and earlier, and the AC10 using firmware...
CVE-2017-16936
Directory Traversal vulnerability in appdatacenter on Shenzhen Tenda Ac9 USAC9V1.0BRV15.03.05.14multiTD01, Ac9 ac9kfV15.03.05.196318cn, Ac15 USAC15V1.0BRV15.03.05.18multiTD01, Ac15 USAC15V1.0BRV15.03.05.19multiTD01, Ac18 USAC18V1.0BRV15.03.05.05multiTD01, and Ac18 ac18kfV15.03.05.196318cn devices...