Lucene search
+L

6 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/04/21 12:00 a.m.•6 views

CVE-2020-28973: Improper Authentication

The ABUS Secvest wireless alarm system FUAA50000 v3.01.17 fails to properly authenticate some requests to its built-in HTTPS interface. Someone can use this vulnerability to obtain sensitive information from the system, such as usernames and passwords. This information can then be used to...

7.5CVSS5.8AI score0.00984EPSS
SaveExploits0References2
zdt
zdt
•added 2020/06/24 12:00 a.m.•222 views

ABUS Secvest Wireless Control Device Missing Encryption Vulnerability

The wireless communication of the ABUS Secvest Wireless Control Device FUBE50001 for transmitting sensitive data like PIN codes or IDs of used proximity chip keys RFID tokens is not encrypted. Product: ABUS Secvest Wireless Control Device FUBE50001 Manufacturer: ABUS Affected Versions: N/A Tested...

8.1CVSS0.4AI score0.00793EPSS
SaveExploits2
NVD
NVD
•added 2019/03/27 3:29 p.m.•28 views

CVE-2019-9860

Due to unencrypted signal communication and predictability of rolling codes, an attacker can "desynchronize" an ABUS Secvest wireless remote control FUBE50014 or FUBE50015 relative to its controlled Secvest wireless alarm system FUAA50000 3.01.01, so that sent commands by the remote control are n...

7.5CVSS7.7AI score0.00841EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/03/27 2:01 p.m.•40 views

CVE-2019-9860

Due to unencrypted signal communication and predictability of rolling codes, an attacker can "desynchronize" an ABUS Secvest wireless remote control FUBE50014 or FUBE50015 relative to its controlled Secvest wireless alarm system FUAA50000 3.01.01, so that sent commands by the remote control are n...

7.7AI score0.00841EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/27 12:00 a.m.•5 views

CVE-2019-9860: Cleartext Transmission of Sensitive Information

Due to unencrypted signal communication and predictability of rolling codes, an attacker can "desynchronize" an ABUS Secvest wireless remote control FUBE50014 or FUBE50015 relative to its controlled Secvest wireless alarm system FUAA50000 3.01.01, so that sent commands by the remote control are n...

7.5CVSS5.8AI score0.00841EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/27 12:00 a.m.•4 views

CVE-2019-9862: Missing Encryption of Sensitive Data

An issue was discovered on ABUS Secvest wireless alarm system FUAA50000 3.01.01 in conjunction with Secvest remote control FUBE50014 or FUBE50015. Because "encrypted signal transmission" is missing, an attacker is able to eavesdrop sensitive data as cleartext for instance, the current rolling cod...

6.5CVSS5.8AI score0.0064EPSS
SaveExploits1References2
Rows per page
Query Builder