2001 matches found
CVE-2025-7705
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions...
CVE-2025-7745
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7745 Modbus TCP buffer overread
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7745 Modbus TCP buffer overread
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7745
CVE-2025-7745 is a buffer over-read vulnerability in ABB AC500 V2. The issue affects AC500 V2 up to version 2.5.2. Publicly available technical details specify a buffer over-read in ABB AC500 V2, with potential for abnormal behavior. The PT-2025-30638 advisory recommends updating ABB AC500 V2 to ...
PT-2025-30638
Name of the Vulnerable Software and Affected Versions ABB AC500 V2 versions through 2.5.2 Description A buffer over-read issue exists in ABB AC500 V2. This can potentially lead to unexpected system behavior. Recommendations Update ABB AC500 V2 to a version later than 2.5.2...
CVE-2025-7705
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions...
CVE-2025-7705
CVE-2025-7705 affects ABB Switch Actuator 4 DU-83330 and ABB Switch actuator, door/light 4 DU-83330-500, all versions. The issue is described as an Active Debug Code vulnerability. The PT-2025-30398 entry confirms the vulnerable components and versions and states there is no information about a f...
CVE-2025-7705 Authentication bypass due to compatibility mode enabled by default
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions...
CVE-2025-7705 Authentication bypass due to compatibility mode enabled by default
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions...
PT-2025-30398
Name of the Vulnerable Software and Affected Versions ABB Switch Actuator 4 DU-83330: All Versions ABB Switch actuator, door/light 4 DU -83330-500: All Versions Description An Active Debug Code issue exists in ABB Switch Actuator 4 DU-83330 and ABB Switch actuator, door/light 4 DU -83330-500...
CISA Releases Six Industrial Control Systems Advisories
CISA released six Industrial Control Systems ICS advisories on July 15, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-196-01 Hitachi Energy Asset Suite ICSA-25-196-02 ABB RMC-100 ICSA-25-196-03 LITEON IC48A...
The vulnerability of the MQTT protocol implementation in the web interface of the microprogramming-based controller ABB RMC-100 and RMC-100-LITE allows a intruder to gain unauthorized access to protected information.
The vulnerability of the MQTT protocol web interface implementation for microprogrammable controllers ABB RMC-100 and RMC-100-LITE lies in the use of a rigidly encrypted cryptographic key. Exploiting this vulnerability could allow an attacker to gain unauthorized access to protected information...
CVE-2025-6072
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.Thi...
CVE-2025-6071
Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. An attacker can gain access to salted information to decrypt MQTT information. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016...
CVE-2025-6073
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer...
CVE-2025-6074
Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data...
CVE-2025-6071
Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. An attacker can gain access to salted information to decrypt MQTT information. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016...
CVE-2025-6072
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.Thi...
CVE-2025-6074
Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data...