ABB Panel Builder 800 DLL Hijacking Vulnerability (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-077-01 ABB Panel Builder 800 DLL Hijacking Vulnerability that was published March 17, 2016, on the NCCIC/ICS-CERT web site. Ivan Sanchez from Nullcode Team has identified a DLL Hijacking vulnerability in the ABB...
ABB RobotWare Remote Code Execution Vulnerability
ABB is a global leader in power and automation technology, ranked among the top 500 companies in the world. ABB RobotWare suffers from a remote code execution vulnerability that could be exploited by an attacker to execute arbitrary code in the context of an affected application...
CVE-2016-4526
ABB DataManagerPro 1.x before 1.7.1 allows local users to gain privileges by replacing a DLL file in the package directory...
CVE-2016-4526
ABB DataManagerPro 1.x before 1.7.1 allows local users to gain privileges by replacing a DLL file in the package directory...
Directory traversal
ABB DataManagerPro 1.x before 1.7.1 allows local users to gain privileges by replacing a DLL file in the package directory...
CVE-2016-4526
CVE-2016-4526 affects ABB DataManagerPro (1.x) prior to 1.7.1. The vulnerability arises from an Uncontrolled Search Path Element (CWE-427) that allows an authenticated local user to swap DLLs in the package directory to gain administrator privileges. Exploitation is local and requires user intera...
CVE-2016-4526: Uncontrolled Search Path Element
ABB DataManagerPro 1.x before 1.7.1 allows local users to gain privileges by replacing a DLL file in the package directory...
ABB DataManagerPro DLL Local Code Execution Vulnerability
ABB DataManagerPro is a data analysis software package from ABB Switzerland. The software allows automatic data collection via Ethernet and database management. ABB DataManagerPro has a local code execution vulnerability. This vulnerability can be exploited by a local attacker to gain privileges ...
(0Day) ABB DataManagerPro File Permissions Privilege Escalation Vulnerability
This vulnerability allows attackers to escalate their privilege to system administrator on vulnerable installations of ABB DataManagerPro. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists...
ABB DataManagerPro Credential Management Vulnerability
OVERVIEW NCCIC/ICS-CERT received a report from Trend Micro’s Zero Day Initiative ZDI concerning a credential management vulnerability in ABB’s DataManagerPro application. Security researcher Andrea Micalizzi reported this vulnerability to ZDI. ABB has produced a new version to mitigate this...
CVE-2016-4527
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors...
CVE-2016-4527
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors...
CVE-2016-4524
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors...
CVE-2016-4516
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors...
CVE-2016-4511
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file...
Default credentials
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors...
Design/Logic Flaw
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file...
Design/Logic Flaw
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors...
CVE-2016-4524
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors...
CVE-2016-4524
CVE-2016-4524 affects ABB PCM600 (OPC Server IEC61850) prior to version 2.7. The vulnerability arises from insecure handling of authentication passwords: the OPC Server IEC61850 credentials are stored in clear text or unsecured temporary locations in the configuration/file artifacts, enabling a l...