CVE-2020-8478
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl all published versions enables an attacker authenticated on the local system to inject data, affecting the online view...
CVE-2020-8471
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash...
Code injection
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling...
Input validation
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA Base all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling...
CVE-2020-8487
Insufficient protection of the inter-process communication functions in ABB System 800xA Base all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl all published versions enables an attacker authenticated on the local system to inject data, affecting the online view...
Xxe
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management all published versions enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management...
Design/Logic Flaw
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody...
Input validation
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
Design/Logic Flaw
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management all published versions enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities...
CVE-2020-8489
ABB System 800xA Information Management is affected by CVE-2020-8489 due to insufficient protection of inter-process communication functions. The vulnerability allows an attacker authenticated on the local system to inject data, potentially altering runtime values stored in the archive or making ...
CVE-2020-8489 ABB System 800xA Inter process communication vulnerability - 800xA Information Management
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management all published versions enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management...
CVE-2020-8488
Affected product: ABB System 800xA Batch Management (all published versions). Vulnerability: Insufficient protection of inter-process communication (IPC) functions enables a local, authenticated attacker to inject data, affecting the User Interface update during batch execution and/or the compare...
CVE-2020-8488 ABB System 800xA Inter process communication vulnerability - 800xA Batch Management
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management all published versions enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities...
CVE-2020-8487
CVE-2020-8487 affects ABB System 800xA Base. The issue is insufficient protection of inter-process communication, allowing an attacker authenticated on the local system to inject data and affect node redundancy handling. Affected products include System 800xA Base (all published versions). Impact...