Lucene search
+L

10640 matches found

Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.12 views

CVE-2023-39462 Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability

Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the...

6.5CVSS7.4AI score0.01536EPSS
SaveExploits0References2
CVE
CVE
added 2024/05/03 1:59 a.m.83 views

CVE-2023-39462

CVE-2023-39462 affects Triangle MicroWorks SCADA Data Gateway. The vulnerability stems from improper validation in the processing of workspace files, allowing remote attackers to upload arbitrary files. Although authentication is required to exploit, the existing authentication mechanism can be b...

6.5CVSS6.8AI score0.01536EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.16 views

CVE-2023-39460 Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability

Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this...

7.2CVSS7.1AI score0.03442EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.18 views

CVE-2023-39458 Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability

Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit th...

5.3CVSS6.8AI score0.00241EPSS
SaveExploits0References2
CVE
CVE
added 2024/05/03 1:59 a.m.59 views

CVE-2023-39457

CVE-2023-39457 affects Triangle MicroWorks SCADA Data Gateway. The vulnerability stems from missing authentication in the default configuration, enabling a remote attacker to bypass authentication and execute arbitrary code with root privileges. Reported under ZDI-20501, the CVSSv3 vector is CVSS...

9.8CVSS9.8AI score0.02032EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.25 views

CVE-2023-39457 Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability

Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw...

9.8CVSS7.8AI score0.02032EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2024/05/03 1:59 a.m.42 views

CVE-2023-39458 Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability

Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit th...

5.3CVSS5.7AI score0.00241EPSS
SaveExploits0References2
CVE
CVE
added 2024/05/03 1:59 a.m.66 views

CVE-2023-39458

Triangle MicroWorks SCADA Data Gateway contains a hard-coded default SSL certificate, allowing authentication bypass for network-adjacent attackers. The flaw is in certificate handling, enabling bypass of authentication on affected installations without required user interaction. Documents consis...

5.3CVSS5.4AI score0.00241EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2024/05/03 1:59 a.m.41 views

CVE-2023-39457 Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability

Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw...

9.8CVSS10AI score0.02032EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.21 views

CVE-2023-38125 Softing edgeAggregator Permissive Cross-domain Policy with Untrusted Domains Remote Code Execution Vulnerability

Softing edgeAggregator Permissive Cross-domain Policy with Untrusted Domains Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Softing edgeAggregator. Authentication is required to exploit this vulnerability. The...

7.5CVSS7.8AI score0.01344EPSS
SaveExploits0References1
CVE
CVE
added 2024/05/03 1:59 a.m.66 views

CVE-2023-38125

CVE-2023-38125 affects Softing edgeAggregator. The root cause is a misconfigured web server that lacks appropriate Content Security Policy headers, enabling a permissive cross-domain policy with untrusted domains. This can allow remote attackers to trigger remote code execution in the context of ...

8.8CVSS8AI score0.01344EPSS
SaveExploits0References1Affected Software3
Cvelist
Cvelist
added 2024/05/03 1:59 a.m.46 views

CVE-2023-38124 Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability

Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit...

7.2CVSS7.7AI score0.59609EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.21 views

CVE-2023-38124 Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability

Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit...

7.2CVSS8AI score0.59609EPSS
SaveExploits0References2
CVE
CVE
added 2024/05/03 1:59 a.m.77 views

CVE-2023-38124

CVE-2023-38124 affects Inductive Automation Ignition Gateway/OPC UA Quick Client Task Scheduling. The flaw stems from exposing a dangerous function in the Ignition Gateway server, allowing remote attackers to execute code with SYSTEM privileges after authenticating. Documents consistently describ...

8.8CVSS7.5AI score0.59609EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2024/05/03 1:59 a.m.30 views

CVE-2023-38123 Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability

Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to explo...

7.5CVSS7.9AI score0.01166EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.17 views

CVE-2023-38122 Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability

Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Although authentication is required to exploit thi...

7.2CVSS7.9AI score0.01875EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/05/03 1:59 a.m.21 views

CVE-2023-38123 Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability

Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to explo...

7.5CVSS6.9AI score0.01166EPSS
SaveExploits0References2
CVE
CVE
added 2024/05/03 1:59 a.m.82 views

CVE-2023-38122

CVE-2023-38122 affects Inductive Automation Ignition OPC UA Quick Client. The flaw is in the web server configuration, arising from missing Content Security Policy headers, enabling a cross-domain policy that can lead to remote code execution. Authentication is required to exploit, but the authen...

7.2CVSS7.5AI score0.01875EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2024/05/03 1:59 a.m.32 views

CVE-2023-38121 Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability

Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability i...

8.3CVSS8.4AI score0.01239EPSS
SaveExploits0References2
CVE
CVE
added 2024/05/03 1:59 a.m.91 views

CVE-2023-38121

CVE-2023-38121 affects Inductive Automation Ignition (OPC UA Quick Client). The vulnerability stems from improper validation of the id parameter in the web interface, enabling cross-site scripting that can lead to remote code execution with SYSTEM privileges. Exploitation requires user interactio...

9CVSS8.2AI score0.01239EPSS
SaveExploits0References2Affected Software1
Rows per page
Query Builder