EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2017-5623

Malware in sbrugna...

7.2CVSS7AI score0.01003EPSS
Exploits0References4
CNVD
CNVD
added 2018/08/23 12:0 a.m.1 views

Philips IntelliSpace Cardiovascular and Xcelera Unknown Search Path or Element Vulnerability

Philips IntelliSpace Cardiovascular ISCV and Xcelera are both products of the Dutch company Philips.Philips ISCV is a cardiac imaging information management system.Xcelera is its predecessor. A security vulnerability exists in Philips ISCV version 3.1 and earlier and Xcelera version 4.1 and...

6.7CVSS7.5AI score0.0019EPSS
Exploits0References1
CNVD
CNVD
added 2018/08/23 12:0 a.m.1 views

Philips IntelliSpace Cardiovascular and Xcelera Privilege Mismanagement Vulnerability

Philips IntelliSpace Cardiovascular ISCV and Xcelera are both products of the Dutch company Philips.Philips ISCV is a cardiac imaging information management system.Xcelera is its predecessor. A security vulnerability exists in Philips ISCV version 2.x and earlier and Xcelera version 4.1 and...

7.8CVSS7.5AI score0.00111EPSS
Exploits0References1
NVD
NVD
added 2018/08/22 6:29 p.m.10 views

CVE-2018-14789

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior, an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges...

6.7CVSS7.3AI score0.0019EPSS
Exploits0References2
NVD
NVD
added 2018/08/22 6:29 p.m.11 views

CVE-2018-14787

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 2.x or prior and Xcelera Version 4.1 or prior, an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local...

7.8CVSS7.8AI score0.00111EPSS
Exploits0References2
Prion
Prion
added 2018/08/22 6:29 p.m.9 views

Code injection

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 2.x or prior and Xcelera Version 4.1 or prior, an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local...

4.6CVSS7.8AI score0.00111EPSS
Exploits0References2Affected Software2
OSV
OSV
added 2018/08/22 6:29 p.m.0 views

CVE-2018-14789

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior, an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges...

6.7CVSS6.1AI score0.0019EPSS
Exploits0References2
OSV
OSV
added 2018/08/22 6:29 p.m.3 views

CVE-2018-14787

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 2.x or prior and Xcelera Version 4.1 or prior, an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local...

7.8CVSS6AI score
Exploits0References2
Cvelist
Cvelist
added 2018/08/22 6:0 p.m.10 views

CVE-2018-14787

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 2.x or prior and Xcelera Version 4.1 or prior, an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local...

7.8AI score0.00111EPSS
Exploits0References2
CVE
CVE
added 2018/08/22 6:0 p.m.46 views

CVE-2018-14787

Philips IntelliSpace Cardiovascular (ISCV) and Xcelera are affected by CVE-2018-14787. ISCV versions 2.x or prior and Xcelera 4.1 or prior permit an attacker with escalated privileges to access folders containing executables where authenticated users have write permissions and to execute arbitrar...

7.8CVSS7.8AI score0.00111EPSS
Exploits0References2Affected Software2
Cvelist
Cvelist
added 2018/08/22 6:0 p.m.12 views

CVE-2018-14789

In Philips' IntelliSpace Cardiovascular ISCV products ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior, an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges...

7.1AI score0.0019EPSS
Exploits0References2
CVE
CVE
added 2018/08/22 6:0 p.m.48 views

CVE-2018-14789

Philips IntelliSpace Cardiovascular (ISCV) and Xcelera are affected by CVE-2018-14789 due to an unquoted search path or element vulnerability in ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior. This flaw can allow an attacker with local access to execute arbitrary code and escalate pri...

6.7CVSS7AI score0.0019EPSS
Exploits0References2Affected Software2
ThreatPost
ThreatPost
added 2018/08/17 7:7 p.m.17 views

Philips Vulnerability Exposes Sensitive Cardiac Patient Information

A vulnerability in the Philips IntelliSpace Cardiovascular ISCV line of medical data management products would allow privilege escalation and arbitrary code execution – opening the door for an attacker to siphon out all kinds of confidential patient information, including medical images and full...

4.6CVSS2AI score0.00111EPSS
Exploits0References3
Prion
Prion
added 2017/11/17 8:29 p.m.14 views

Design/Logic Flaw

The workstation logging function in Philips IntelliSpace Cardiovascular ISCV 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements...

4CVSS7AI score0.01003EPSS
Exploits0References3Affected Software2
NVD
NVD
added 2017/11/17 8:29 p.m.12 views

CVE-2017-14111

The workstation logging function in Philips IntelliSpace Cardiovascular ISCV 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements...

7.2CVSS7AI score0.01003EPSS
Exploits0References3
OSV
OSV
added 2017/11/17 8:29 p.m.1 views

CVE-2017-14111

The workstation logging function in Philips IntelliSpace Cardiovascular ISCV 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements...

7.2CVSS5.8AI score
Exploits0References3
Cvelist
Cvelist
added 2017/11/17 8:0 p.m.15 views

CVE-2017-14111

The workstation logging function in Philips IntelliSpace Cardiovascular ISCV 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements...

7.1AI score0.01003EPSS
Exploits0References3
CVE
CVE
added 2017/11/17 8:0 p.m.46 views

CVE-2017-14111

CVE-2017-14111 affects Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier. The root cause is insufficiently protected credentials: credentials are stored in plaintext in system files, enabling an attacker with elevated privileges to access sensitive data o...

7.2CVSS7AI score0.01003EPSS
Exploits0References3Affected Software2
CNVD
CNVD
added 2017/11/16 12:0 a.m.2 views

Philips IntelliSpace Cardiovascular System and Xcelera System Plaintext Storage Vulnerability

The Philips IntelliSpace Cardiovascular and Xcelera systems predecessor to IntelliSpace Cardiovascular are comprehensive cardiac imaging and information management software. The Philips IntelliSpace Cardiovascular System and Xcelera System have a plaintext storage vulnerability where credentials...

7.2CVSS6.8AI score0.01003EPSS
Exploits0References1
Rows per page