1055 matches found
Siemens SIMATIC WinCC security vulnerabilities
SIMATIC WinCC is a supervisory control and data acquisition SCADA system. A local code execution vulnerability exists in Siemens SIMATIC WinCC, which can be exploited by an attacker to inject arbitrary code and escalate privileges...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in SIMATIC, SICAM, SIMOTION, WinCC, Solid Edge and Scalance products. The vulnerabilities allow a malicious party potentially capable of carrying out attacks that can result in the following categories of damage: Denial-of-Service DoS Manipulation of data...
Siemens SIMATIC WinCC V7
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SIMATIC WinCC
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2023-28829: Use of Obsolete Function
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
PT-2023-3622 · Microsoft +1 · Windows +6
Name of the Vulnerable Software and Affected Versions: SIMATIC NET PC Software versions V14 through V15 SIMATIC PCS 7 versions V8.2 through V9.1 SIMATIC WinCC versions prior to V8.0 SINAUT Software ST7sc affected versions not specified Description: The issue is related to the use of outdated...
CVE-2023-30897: Incorrect Permission Assignment for Critical Resource
A vulnerability has been identified in SIMATIC WinCC All versions V7.5.2.13. Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation. This could allow an authenticated local attacker to inject arbitrary...
PT-2023-3767 · Siemens · Simatic Wincc
Name of the Vulnerable Software and Affected Versions: SIMATIC WinCC versions prior to V7.5.2.13 Description: The issue is related to improper permission assignment for a critical resource in the SCADA system. This could allow an authenticated local attacker to inject arbitrary code and escalate...
Siemens SIMATIC WinCC OA Ultralight Client Parameter Injection Vulnerability
SIMATIC WinCC Open Architecture OA is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that require specific system requirements or functionality. A parameter injection...
CVE-2022-44731
A vulnerability has been identified in SIMATIC WinCC OA V3.15 All versions V3.15 P038, SIMATIC WinCC OA V3.16 All versions V3.16 P035, SIMATIC WinCC OA V3.17 All versions V3.17 P024, SIMATIC WinCC OA V3.18 All versions V3.18 P014. The affected component allows to inject custom arguments to the...
CVE-2022-44731
A vulnerability has been identified in SIMATIC WinCC OA V3.15 All versions V3.15 P038, SIMATIC WinCC OA V3.16 All versions V3.16 P035, SIMATIC WinCC OA V3.17 All versions V3.17 P024, SIMATIC WinCC OA V3.18 All versions V3.18 P014. The affected component allows to inject custom arguments to the...
Code injection
A vulnerability has been identified in SIMATIC WinCC OA V3.15 All versions V3.15 P038, SIMATIC WinCC OA V3.16 All versions V3.16 P035, SIMATIC WinCC OA V3.17 All versions V3.17 P024, SIMATIC WinCC OA V3.18 All versions V3.18 P014. The affected component allows to inject custom arguments to the...
CVE-2022-44731
The CVE-2022-44731 vulnerability affects Siemens SIMATIC WinCC OA Ultralight Client. The Ultralight Client backend can be injected with custom arguments under certain conditions when started via the web interface, enabling an authenticated remote attacker to inject parameters (e.g., open attacker...
PT-2022-27287 · Siemens · Simatic Wincc
Name of the Vulnerable Software and Affected Versions: SIMATIC WinCC OA versions prior to V3.15 P038 SIMATIC WinCC OA versions prior to V3.16 P035 SIMATIC WinCC OA versions prior to V3.17 P024 SIMATIC WinCC OA versions prior to V3.18 P014 Description: A vulnerability allows injecting custom...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in Mendix, among others, Nucleus NET, RUGGEDCOM, SCALANCE, SICAM, SIMATIC, SIPROTEC and SIMATIC WinCC-OA. The vulnerabilities allow a malicious potentially able to launch attacks that result in the following categories of damage: Cross-Site Request Forgery XSRF...
CVE-2022-44731
A vulnerability has been identified in SIMATIC WinCC OA V3.15 All versions V3.15 P038, SIMATIC WinCC OA V3.16 All versions V3.16 P035, SIMATIC WinCC OA V3.17 All versions V3.17 P024, SIMATIC WinCC OA V3.18 All versions V3.18 P014. The affected component allows to inject custom arguments to the...
CVE-2022-44731: Improper Neutralization of Argument Delimiters in a Command
A vulnerability has been identified in SIMATIC WinCC OA V3.15 All versions V3.15 P038, SIMATIC WinCC OA V3.16 All versions V3.16 P035, SIMATIC WinCC OA V3.17 All versions V3.17 P024, SIMATIC WinCC OA V3.18 All versions V3.18 P014. The affected component allows to inject custom arguments to the...
CVE-2022-44731
A vulnerability has been identified in SIMATIC WinCC OA V3.15 All versions V3.15 P038, SIMATIC WinCC OA V3.16 All versions V3.16 P035, SIMATIC WinCC OA V3.17 All versions V3.17 P024, SIMATIC WinCC OA V3.18 All versions V3.18 P014. The affected component allows to inject custom arguments to the...
Siemens products: Parameter injection vulnerabilities
SIMATIC WinCC Open Architecture OA is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that require specific system requirements or functionality. A parameter injection...
Multiple Siemens Products Cross-Site Request Forgery Vulnerability
SIMATIC Drive Controllers are designed for the automation of production machines, combining the functionality of SIMATIC S7-1500 CPUs and SINAMICS S120 Drive Controllers.SIMATIC PC Station is a software component that manages the interface between SIMATIC software products and the PC. SIMATIC...