Your Smart Christmas Lights Are Safer Than They Were Last Year
Thinking about putting up smart Christmas lights but worried about your internet of things IoT security? You can rest a bit easier this year because at least one festive light option is a bit safer than it used to be, new research has found. Manufacturers of the Twinkly smart lights have taken in...
CVE-2017-11580
Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device coul...
Memory corruption
Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device coul...
CVE-2017-11580
Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device coul...
CVE-2017-12701
BMC Medical Luna CPAP Machines released prior to July 1, 2017, contain an improper input validation vulnerability which may allow an authenticated attacker to crash the CPAP's Wi-Fi module resulting in a denial-of-service condition...
Input validation
BMC Medical Luna CPAP Machines released prior to July 1, 2017, contain an improper input validation vulnerability which may allow an authenticated attacker to crash the CPAP's Wi-Fi module resulting in a denial-of-service condition...
CVE-2017-12701
BMC Medical Luna CPAP Machines released prior to July 1, 2017, contain an improper input validation vulnerability which may allow an authenticated attacker to crash the CPAP's Wi-Fi module resulting in a denial-of-service condition...
CVE-2017-12701
CVE-2017-12701 affects BMC Medical Luna CPAP Machines released before 1 July 2017. It is an improper input validation vulnerability that could allow an authenticated attacker to crash the device’s Wi‑Fi module, causing a denial-of-service while the therapy function remains unaffected. The issue i...
Design/Logic Flaw
Ring formerly DoorBot video doorbells allow remote attackers to obtain sensitive information about the wireless network configuration by pressing the set up button and leveraging an API in the GainSpan Wi-Fi module...
CVE-2015-4400
Ring formerly DoorBot video doorbells allow remote attackers to obtain sensitive information about the wireless network configuration by pressing the set up button and leveraging an API in the GainSpan Wi-Fi module...
CVE-2015-4400
Ring formerly DoorBot video doorbells allow remote attackers to obtain sensitive information about the wireless network configuration by pressing the set up button and leveraging an API in the GainSpan Wi-Fi module...
ICSMA-17-227-01_BMC Medical and 3B Medical Luna CPAP Machine
OVERVIEW MedSec has identified an improper input validation vulnerability in BMC Medical’s and 3B Medical’s Luna continuous positive airway pressure CPAP therapy machine. For devices released after July 1, 2017, this vulnerability has been addressed. For devices released prior to July 1, 2017, BM...