22259 matches found
CVE-2024-8232
SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication...
CVE-2024-8232
CVE-2024-8232 affects SpiderControl SCADA Web Server (iniNet Solutions GmbH). The vulnerability allows unauthenticated upload of specially crafted files via the web server, with potential to log in or execute arbitrary code. Affected products in ICS advisories include SpiderControl SCADA Web Serv...
CVE-2024-8232 iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type
SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication...
CVE-2024-8232 iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type
SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication...
CVE-2023-28827
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
CVE-2023-30756
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
CVE-2023-30756
CVE-2023-30756 affects Siemens SIMATIC devices (CP 1242-7 V2, CP 1243-1/IEC, 1243-7 LTE, 1243-8 IRC, HMI Comfort Panels, IPC DiagBase/DiagMonitor, WinCC Runtime Advanced, SIPLUS TIM 1531 IRC, TIM 1531 IRC) and related SIPLUS variants. The vulnerability is a NULL pointer dereference in the devices...
CVE-2023-30755
Siemens CVE-2023-30755 is a NULL POINTER DEREFERENCE affecting multiple SIMATIC/Siemens products (e.g., CP 1242-7 V2, CP 1243 variants, HMI Comfort Panels, IPC DiagBase/DiagMonitor, WinCC Runtime Advanced, SIPLUS TIM 1531 IRC, TIM 1531 IRC). The web server does not properly handle shutdown/reboot...
CVE-2023-30755
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
CVE-2023-28827
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
CVE-2023-28827: NULL Pointer Dereference
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
CVE-2023-30756: NULL Pointer Dereference
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
CVE-2024-8232: Unrestricted Upload of File with Dangerous Type
SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication...
iniNet Solutions SpiderControl SCADA Web Server code issues and vulnerabilities
iniNet Solutions SpiderControl SCADA Web Server is a server from iniNet Solutions. A code issue vulnerability exists in iniNet Solutions SpiderControl SCADA Web Server. An attacker could exploit the vulnerability to upload specially crafted malicious files...
Siemens SIMATIC code-related vulnerabilities
SIMATIC CP 1242 and CP 1243 associated processors connect SIMATIC S7-1200 controllers to a wide area network WAN. They provide integrated security features such as firewalls, virtual private networks VPNs, and support for other data encryption protocols.SIMATIC HMI Panels are used for operator...
Siemens SIMATIC code-related vulnerabilities
SIMATIC CP 1242 and CP 1243 associated processors connect SIMATIC S7-1200 controllers to a wide area network WAN. They provide integrated security features such as firewalls, virtual private networks VPNs, and support for other data encryption protocols.SIMATIC HMI Panels are used for operator...
Siemens SIMATIC code-related vulnerabilities
SIMATIC CP 1242 and CP 1243 associated processors connect SIMATIC S7-1200 controllers to a wide area network WAN. They provide integrated security features such as firewalls, virtual private networks VPNs, and support for other data encryption protocols.SIMATIC HMI Panels are used for operator...
PT-2024-7079 · Siemens · Simatic Cp 1242-7 V2 +11
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 1242-7 V2 incl. SIPLUS variants versions prior to V3.5.20 SIMATIC CP 1243-1 incl. SIPLUS variants versions prior to V3.5.20 SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants versions prior to V3.5.20 SIMATIC CP 1243-1 IEC incl. SIPLUS...
PT-2024-7668 · Siemens · Simatic Cp 1242-7 V2 +11
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 1242-7 V2 incl. SIPLUS variants versions prior to V3.5.20 SIMATIC CP 1243-1 incl. SIPLUS variants versions prior to V3.5.20 SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants versions prior to V3.5.20 SIMATIC CP 1243-1 IEC incl. SIPLUS...
httpd: Security issues via backend applications whose response headers are malicious or exploitable
A flaw was found in httpd. Backend applications whose response headers are malicious or exploitable may allow information disclosure, server-side request forgery SSRF or local script execution...