1027 matches found
CVE-2025-8730 Belkin F9K1009/F9K1010 Web Interface hard-coded credentials
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been...
CVE-2025-8730 Belkin F9K1009/F9K1010 Web Interface hard-coded credentials
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been...
The vulnerability of the web interface of D-Link DIR-300 and DIR-600 microprogrammed software routers allows a hacker to execute arbitrary commands.
The vulnerability of the web interfaces of D-Link DIR-300 and DIR-600 microprogrammed software routers is related to the failure to eliminate special elements used in the operating system’s processing of the pingIp parameter. Exploiting this vulnerability allows a remote attacker to execute...
CVE-2013-10050
CVE-2013-10050 affects D-Link DIR-300 (rev A, v1.05) and DIR-615 (rev D, v4.13). An authenticated user can exploit the tools_vct.xgi CGI endpoint to inject commands via pingIp, leading to full device compromise (telnet daemon and root shell). The flaw is tied to firmware exposing tools_vct.xgi on...
CVE-2025-51569
CVE-2025-51569 describes a cross-site scripting (XSS) vulnerability in the LB-Link BL-CPE300M web interface. The issue stems from the endpoint /goform/goform_get_cmd_process, where input in the cmd parameter is not properly sanitized before being reflected into a text/html response, enabling an a...
CVE-2025-51569
A cross-site scripting XSS vulnerability exists in the LB-Link BL-CPE300M 01.01.02P42U1406 router's web interface. The /goform/goformgetcmdprocess endpoint fails to sanitize user input in the cmd parameter before reflecting it into a text/html response. This allows unauthenticated attackers to...
The vulnerability of the web interface of the IBM Robotic Process Automation software allows a perpetrator to disclose account information during a secure session.
The vulnerability of the web interface of the IBM Robotic Process Automation software lies in the lack of measures taken to protect the structure of the web page. Exploiting this vulnerability allows a malicious actor to obtain login credentials during a secure session by executing the code...
CVE-2025-3508 Certain HP DesignJet products – Information disclosure
Certain HP DesignJet products may be vulnerable to information disclosure though printer's web interface allowing unauthenticated users to view sensitive print job information...
PT-2025-30589
Name of the Vulnerable Software and Affected Versions SonicWall SMA100 series Description A stack-based buffer overflow vulnerability in the web interface allows a remote, unauthenticated attacker to cause a Denial of Service DoS or potentially achieve code execution. Recommendations At the momen...
The vulnerability of the System Time module in the D-LINK DIR-818LW router’s software management web interface allows a hacker to execute arbitrary commands.
The vulnerability of the System Time module in the D-LINK DIR-818LW router’s software management web interface is related to the lack of measures taken to neutralize special elements during the processing of the NTP Server parameter. Exploiting this vulnerability allows a remote attacker to execu...
CVE-2025-41425 DuraComm DP-10iN-100-MU Cross-site Scripting
DuraComm SPM-500 DP-10iN-100-MU is vulnerable to a cross-site scripting attack. This could allow an attacker to prevent legitimate users from accessing the web interface...
DuraComm SPM-500 DP-10iN-100-MU 跨站脚本漏洞
The DuraComm SPM-500 DP-10iN-100-MU is a DC power distribution panel from DuraComm USA. A cross-site scripting vulnerability exists in the DuraComm SPM-500 DP-10iN-100-MU, which stems from susceptibility to cross-site scripting attacks that could prevent a legitimate user from accessing the web...
The vulnerability in the web interface for managing software tools used to create reports for Cisco Unified Intelligence Center, as well as for multimedia and distributed contact centers like Cisco Unified Contact Center Enterprise, allows attackers to perform SRF attacks.
The vulnerability in the web interface for managing software tools used to create reports for Cisco Unified Intelligence Center, as well as for multimedia and distributed contact centers like Cisco Unified Contact Center Enterprise, stems from forged requests at the server side, resulting from...
CVE-2025-34115 OP5 Monitor <= 7.1.9 Authenticated Command Execution via command_test.php
An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmdstr' parameter in the commandtest.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web...
CVE-2025-7574 LB-LINK BL-WR9000 Web Interface lighttpd.cgi restore improper authentication
A vulnerability, which was classified as critical, was found in LB-LINK BL-AC1900, BL-AC2100AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. Affected is the function reboot/restore of the file /cgi-bin/lighttpd.cgi of the component Web Interface. The manipulation leads to...
CVE-2025-50121
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default...
CVE-2025-52950
Juniper Networks Security Director has a Missing Authorization vulnerability (CVE-2025-52950) where an unauthenticated network-based attacker can read or tamper with sensitive resources through the web interface. The issue arises from endpoints that do not validate authorization, allowing access ...
CVE-2025-50121
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default...
CVE-2025-50121
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default...
The vulnerability of the web interface of the software for managing the infrastructure of the EcoStruxure IT Data Center Expert allows a perpetrator to execute arbitrary code.
The vulnerability of the web interface of the software for managing the infrastructure of the EcoStruxure IT Data Center Expert is related to the failure to take measures to neutralize specific elements. Exploiting this vulnerability allows a malicious actor to execute arbitrary code by creating ...