679 matches found
CVE-2023-38346: Improper Limitation of a Pathname to a Restricted Directory
An issue was discovered in Wind River VxWorks 6.9 and 7. The function tarExtract implements TAR file extraction and thereby also processes files within an archive that have relative or absolute file paths. A developer using the "tarExtract" function may expect that the function will strip leading...
PT-2023-5463 · Wind River · Vxworks
Name of the Vulnerable Software and Affected Versions: Wind River VxWorks versions 6.9 through 7 Description: An issue was discovered in the tarExtract function, which implements TAR file extraction and processes files within an archive that have relative or absolute file paths. This could lead t...
The vulnerability of the IKE protocol implementation in real-time operating systems like Wind River VxWorks allows attackers to trigger service failures or gain access to confidential information.
The vulnerability of the IKE protocol implementation in real-time operating systems like Wind River VxWorks relates to reading beyond the boundary. Exploiting this vulnerability can allow a malicious actor to cause service failures or gain access to confidential information...
Siemens RADIUS Client of SIPROTEC 5 Devices Loop with Unreachable Exit Condition (CVE-2022-38767)
An issue was discovered in Wind River VxWorks 6.9 and 7, that allows a specifically crafted packet sent by a Radius server, may cause Denial of Service during the IP Radius access procedure. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
SUSE CVE-2005-3804
Cisco IP Phone VoIP 7920 1.08 listens to UDP port 17185 to support a VxWorks debugger, which allows remote attackers to obtain sensitive information and cause a denial of service...
ABB Integer Underflow in Wind River VxWorks (CVE-2019-12255)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Improper Neutralization of Argument Delimiters in a Command in Wind River VxWorks (CVE-2019-12258)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Heap-Based Buffer Overflow in Wind River VxWorks (CVE-2019-12257)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Improper Restriction of Operations Within the Bounds of a Memory Buffer in Wind River VxWorks (CVE-2019-12260)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Concurrent Execution Using Shared Resource with Improper Synchronization in Wind River VxWorks (CVE-2019-12263)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Improper Restriction of Operations Within the Bounds of a Memory Buffer in Wind River VxWorks (CVE-2019-12261)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Improper Neutralization of Argument Delimiters in a Command in Wind River VxWorks (CVE-2019-12262)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
ABB Improper Neutralization of Argument Delimiters in a Command in Wind River VxWorks (CVE-2019-12264)
Wind River is the provider of a real time operating system called VxWorks which is used in the embedded software of the PM 877 Controller. Wind River has announced security vulnerabilities in the VxWorks TCP/IP stack IPnet and management of memory block size Bad Alloc. The controller PM 877 is...
Hitachi Energy's RTU500 Series Product (UPDATE B)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Hitachi Energy Equipment : RTU500 Series Vulnerabilities : Type Confusion, Observable Timing Discrepancy, Out-of-bounds Read, Infinite Loop, Classic Buffer Overflow 2. RISK EVALUATION...
Siemens Multiple RTOS Integer Overflow or Wraparound (CVE-2020-35198)
An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc. As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption...
Siemens Multiple RTOS Integer Overflow or Wraparound (CVE-2020-28895)
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc. As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption. SCALANCE X-200, X-200IRT, and X-300...
Siemens SCALANCE and SIMATIC Uncontrolled Resource Consumption (CVE-2019-19301)
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALAN...
The vulnerability of real-time operating systems like Wind River VxWorks arises from executing a loop with an unreachable exit condition, allowing attackers to cause system failures.
The vulnerability of real-time operating systems like Wind River VxWorks lies in the execution of a loop with an unavailable exit condition. Exploiting this vulnerability allows a malicious actor to cause a service failure by sending a specially crafted package from the RADIUS server...
Hitachi Energy Relion 670/650/SAM600-IO Initialization of a Resource with an Insecure Default (CVE-2021-35535)
Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process...
Siemens RADIUS Client of SIPROTEC 5 Devices
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...