CVE-2023-5401
CVE-2023-5401 affects Honeywell Experion products (PKS, LX, PlantCruise by Experion, Safety Manager, Safety Manager SC). A stack-based overflow can be triggered when the server receives a malformed message based on specified key values, potentially enabling remote code execution or a crash over t...
CVE-2023-5400
Server receiving a malformed message based on a using the specified key values can cause a heap overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5400
The CVE-2023-5400 issue is a heap-based buffer overflow in Honeywell Experion family components (Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager/Safety Manager SC) that triggers when the server receives a malformed message based on specified key values. Root cause: heap overflo...
CVE-2023-5398
Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5398
Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5398
CVE-2023-5398 affects Honeywell Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, and Safety Manager SC. The vulnerability arises from the server receiving a malformed message based on a list of IPs, which can trigger a heap-based/ memory corruption leading to a denial-of-servic...
CVE-2023-5397
CVE-2023-5397 affects Honeywell Experion PKS/LX/PlantCruise/Safety Manager and Safety Manager SC. The root cause is a server receiving a malformed message to establish a new connection, enabling remote code execution or causing a failure. Public documentation from multiple sources confirms an imp...
CVE-2023-5395
Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5395
Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning...
CVE-2023-5394
Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations...
CVE-2023-5394
Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations...
CVE-2023-5393
Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and...
Anatsa Android Trojan Bypasses Google Play Security, Expands Reach to New Countries
The Android banking trojan known as Anatsa has expanded its focus to include Slovakia, Slovenia, and Czechia as part of a new campaign observed in November 2023. "Some of the droppers in the campaign successfully exploited the accessibility service, despite Google Play's enhanced detection and...
CVE-2023-5390
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends...
Design/Logic Flaw
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files...
CVE-2024-0891
A vulnerability was found in hongmaple octopus 1.0. It has been declared as problematic. Affected by this vulnerability is an unknown functionality. The manipulation of the argument description with the input alertdocument.cookie leads to cross site scripting. The attack can be launched remotely...
Cross site scripting
A vulnerability was found in hongmaple octopus 1.0. It has been declared as problematic. Affected by this vulnerability is an unknown functionality. The manipulation of the argument description with the input alertdocument.cookie leads to cross site scripting. The attack can be launched remotely...
tRPC vs GraphQL
Deciphering the Cloud Conundrum: An Introduction to tRPC & GraphQL The dynamic domain of cloud technology presents a couple of instrumental methodologies in the arena of APIs: tRPC and GraphQL. Each serves as a potent asset for developers in crafting applications that are resilient, scalable, and...
java-11-openjdk security update
1:11.0.22.0.7-1.0.1 - link atomic for ix86 build 1:11.0.22.0.7-1 - Update to jdk-11.0.22+7 GA - Update release notes to 11.0.22+7 - Switch to GA mode for release - This tarball is embargoed until 2024-01-16 @ 1pm PT. - Resolves: RHEL-20966 1:11.0.22.0.6-0.1.ea - Update to jdk-11.0.22+6 EA - Updat...
java-1.8.0-openjdk security and bug fix update
1:1.8.0.402.b06-0.1.ea - Update to shenandoah-jdk8u402-b06 GA - Update release notes for shenandoah-8u402-b06. - Drop local copy of JDK-8312489 which is now included upstream - Switch to GA mode. - This tarball is embargoed until 2024-01-16 @ 1pm PT. - Resolves: RHEL-17914 - Resolves: RHEL-20965...