Lucene search
+L

27 matches found

Veeam
Veeam
•added 2012/05/05 12:00 a.m.•26 views

Naming requirement for correct functioning of the "Guest to Agent Relationship" feature

Challenge To make the VM and OpsMgr Agent integration work properly, it is necessary that VMs discovered by the VMGUEST contains OpsMgr Agent discovery have an identical display name and NETBIOS name. Cause If the VMware display name is different from the NETBIOS name, the VM will have two source...

6.9AI score
SaveExploits0
Veeam
Veeam
•added 2011/10/06 12:00 a.m.•29 views

The service discovery portion of the SPI frequently fails due to a timeout

Challenge Due to weak virtual infrastructure, the discovery process takes more time than the default timeout in the HP agent. Cause Performance related problems on VMware vCenter side. Solution Workaround is to adjust settings of the agent timeout by using the following commands: ovconfchg -ns...

7.1AI score
SaveExploits0
NVD
NVD
•added 2011/02/17 6:00 p.m.•27 views

CVE-2011-0355

Cisco Nexus 1000V Virtual Ethernet Module VEM 4.04 SV11 through SV13b, as used in VMware ESX 4.0 and 4.1 and ESXi 4.0 and 4.1, does not properly handle dropped packets, which allows guest OS users to cause a denial of service ESX or ESXi host OS crash by sending an 802.1Q tagged packet over an...

7.8CVSS6.5AI score0.01983EPSS
SaveExploits0References12
Prion
Prion
•added 2011/02/17 6:00 p.m.•29 views

Design/Logic Flaw

Cisco Nexus 1000V Virtual Ethernet Module VEM 4.04 SV11 through SV13b, as used in VMware ESX 4.0 and 4.1 and ESXi 4.0 and 4.1, does not properly handle dropped packets, which allows guest OS users to cause a denial of service ESX or ESXi host OS crash by sending an 802.1Q tagged packet over an...

7.8CVSS7AI score0.01983EPSS
SaveExploits0References12Affected Software3
CVE
CVE
•added 2011/02/17 5:00 p.m.•76 views

CVE-2011-0355

The CVE-2011-0355 issue affects Cisco Nexus 1000V Virtual Ethernet Module (VEM) Release 4.0(4) SV1(1) through SV1(3b) used with VMware ESX/ESXi 4.0–4.1. A flaw in how the VEM handles dropped packets allows a guest OS user to trigger a denial of service (host OS crash) by sending an 802.1Q tagged ...

7.8CVSS6.7AI score0.01983EPSS
SaveExploits0References12Affected Software3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2011/02/17 12:00 a.m.•4 views

CVE-2011-0355: Undefined Security Weakness

Cisco Nexus 1000V Virtual Ethernet Module VEM 4.04 SV11 through SV13b, as used in VMware ESX 4.0 and 4.1 and ESXi 4.0 and 4.1, does not properly handle dropped packets, which allows guest OS users to cause a denial of service ESX or ESXi host OS crash by sending an 802.1Q tagged packet over an...

7.8CVSS5.8AI score0.01983EPSS
SaveExploits0References2
VMware
VMware
•added 2011/02/05 12:00 a.m.•48 views

VMSA-2011-0002:Cisco Nexus 1000V VEM updates address denial of service in VMware ESX/ESXi

VMSA-2011-0002 Cisco Nexus 1000V VEM updates address denial of service in VMware ESX/ESXi VMware Security Advisory VMware Security Advisory Advisory ID: VMSA-2011-0002 VMware Security Advisory Synopsis: Cisco Nexus 1000V VEM updates address denial of service in VMware ESX/ESXi VMware Security...

7.8CVSS6.3AI score0.01983EPSS
SaveExploits0
Rows per page