Prion
Prion
added 2020/01/24 8:15 p.m.23 views

Race condition

CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition...

4CVSS6.5AI score0.01884EPSS
SaveExploits1References2Affected Software15
CVE
CVE
added 2020/01/24 7:31 p.m.69 views

CVE-2020-7052

CVE-2020-7052 affects CODESYS Control V3, Gateway V3 and HMI V3 before 3.5.15.30. The issue is uncontrolled memory allocation that can lead to a remote denial of service. The connected sources reiterate the same affected products and condition; no explicit patch/version details are provided in th...

6.5CVSS6.4AI score0.01884EPSS
SaveExploits1References2Affected Software15
Cvelist
Cvelist
added 2020/01/24 7:31 p.m.26 views

CVE-2020-7052

CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition...

6.5AI score0.01884EPSS
SaveExploits1References2
Openbugbounty
Openbugbounty
added 2020/01/16 9:50 a.m.8 views

videopro.com.au Cross Site Scripting vulnerability OBB-1068550

Following coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: &nbsp&nbsp&nbsp&nbsp&nbsp&nbspa. verified the vulnerability and confirmed its existence; &nbsp&nbsp&nbsp&nbsp&nbsp&nbspb. notified the website operator about its existence...

0.1AI score
SaveExploits0
ICS
ICS
added 2020/01/16 12:00 a.m.66 views

Siemens TIA Portal (Update F)

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: TIA Portal Vulnerability: Path Traversal 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-20-014-05 Siemens TIA Portal Update E that was published June...

7.8CVSS7.8AI score0.00433EPSS
SaveExploits0References4
ICS
ICS
added 2020/01/14 12:00 a.m.88 views

Siemens SCALANCE X Switches (Update B)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE X Switches Vulnerability: Missing Authentication for Critical Function 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled...

8.6CVSS8.8AI score0.01389EPSS
SaveExploits0References11
ICS
ICS
added 2020/01/14 12:00 a.m.46 views

Siemens SINAMICS PERFECT HARMONY GH180

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Vulnerability: Protection Mechanism Failure 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized attacker with physical access...

7.2CVSS6.8AI score0.00316EPSS
SaveExploits0References9
ICS
ICS
added 2020/01/14 12:00 a.m.59 views

OSIsoft PI Vision

1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: OSIsoft LLC Equipment: PI Vision Vulnerabilities: Improper Access Control, Cross-site Request Forgery CSRF, Cross-site Scripting, Inclusion of Sensitive Information in Log Files 2. RISK EVALUATION...

8.8CVSS7.3AI score0.01096EPSS
SaveExploits0References5
ICS
ICS
added 2020/01/14 12:00 a.m.147 views

GE PACSystems RX3i

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE/Emerson Equipment: PACSystems RX3i Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause the system to change to halt-mode,...

7.8CVSS7.8AI score0.01549EPSS
SaveExploits0References5
ICS
ICS
added 2020/01/14 12:00 a.m.65 views

Siemens SINEMA Server

1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINEMA Server Vulnerability: Incorrect Privilege Assignment 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with a valid session, with...

9.9CVSS9.6AI score0.01208EPSS
SaveExploits0References9
CVE
CVE
added 2020/01/09 1:00 p.m.50 views

CVE-2014-2650

The CVE concerns Unify OpenStage / OpenScape Desk Phone IP (pre-V3 R3.11.0) where the web-based management interface is vulnerable to OS command injection. Root cause is improper handling of input in the management UI, enabling an attacker to execute arbitrary commands on the device. CVSS data in...

10CVSS9.6AI score0.02574EPSS
SaveExploits0References2Affected Software1
ICS
ICS
added 2019/12/17 12:00 a.m.51 views

GE S2020/S2020G Fast Switch 61850

1. EXECUTIVE SUMMARY CVSS v3 4.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: GE S2020/S2020G Fast Switch 61850 Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to inject arbitrary code...

5.4CVSS6.5AI score0.01553EPSS
SaveExploits0References5
Openbugbounty
Openbugbounty
added 2019/12/12 7:11 p.m.11 views

siamfreestyle.com Cross Site Scripting vulnerability

Security Researcher g0bl1nsec Helped patch 3608 vulnerabilities Received 4 Coordinated Disclosure badges Received 3 recommendations , a holder of 4 badges for responsible and coordinated disclosure, found a security vulnerability affecting siamfreestyle.com website and its users. Following...

6.5AI score
SaveExploits0
ICS
ICS
added 2019/12/12 12:00 a.m.85 views

Omron PLC CJ and CS Series

1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Omron Equipment : PLC CJ and CS Series Vulnerabilities : Authentication Bypass by Spoofing, Authentication Bypass by Capture-replay, Unrestricted Externally Accessible Lock 2. UPDATE This updated...

9.8CVSS9.6AI score0.0211EPSS
SaveExploits0References5
ICS
ICS
added 2019/12/10 12:00 a.m.95 views

Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC S7-1200 and S7-1500 CPU families Vulnerabilities: Use of a Broken or Risky Cryptographic Algorithm, Missing Support for Integrity Check 2. UPDATE INFORMATION This updated...

7.5CVSS6.7AI score0.00978EPSS
SaveExploits0References5
ICS
ICS
added 2019/12/10 12:00 a.m.71 views

Siemens SCALANCE W700 and W1700

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: SCALANCE W700 and W1700 Vulnerability: Improper Enforcement of Message Integrity During Transmission in a Communication Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could...

6.5CVSS6.8AI score0.01476EPSS
SaveExploits0References9
ICS
ICS
added 2019/12/10 12:00 a.m.61 views

Siemens and PKE SiNVR, SiVMS Video Server (Update A)

1. EXECUTIVE SUMMARY --------- Begin Update A Part 1 of 6 --------- CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendors: Siemens and PKE Equipment: SiNVR, SiVMS Video Servers Vulnerabilities: Missing Authentication for Critical Function, Weak Cryptography for Passwords...

9.9CVSS7.6AI score0.02652EPSS
SaveExploits0References5
ThreatPost
ThreatPost
added 2019/11/21 7:15 p.m.88 views

Microsoft Outlook for Android Bug Opens Door to XSS

Users of the Microsoft Outlook for Android app should update their apps to avoid a range of attacks. The bug CVE-2019-1460 would allow an attacker to perform cross-site scripting XSS attacks on the affected systems and run scripts in the security context of the current user, according to...

3.5CVSS7.1AI score0.24563EPSS
SaveExploits0References8
ICS
ICS
added 2019/11/14 12:00 a.m.113 views

Omron CX-Supervisor (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Omron Equipment: CX-Supervisor Vulnerability: Use of Obsolete Function 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-19-318-04 Omron CX-Supervisor...

8.8CVSS8.8AI score0.01735EPSS
SaveExploits0References5
ICS
ICS
added 2019/11/12 12:00 a.m.71 views

Siemens S7-1200 and S7-200 SMART CPUs (Update B)

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION : Low skill level to exploit Vendor : Siemens Equipment: S7-1200 CPU family including SIPLUS variants; S7-200 SMART CPU family Vulnerability : Exposed Dangerous Method or Function 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory...

6.8CVSS6.6AI score0.00532EPSS
SaveExploits0References9