Lucene search
+L

15954 matches found

Cvelist
Cvelist
•added 2025/10/06 6:52 a.m.•38 views

CVE-2025-58583 User Enumeration

The application provides access to a login protected H2 database for caching purposes. The username is prefilled...

5.3CVSS0.00364EPSS
SaveExploits0References6
NVD
NVD
•added 2025/10/06 6:15 a.m.•22 views

CVE-2025-11323

A vulnerability was determined in UTT 1250GW up to v2v3.2.2-200710. Affected is the function strcpy of the file /goform/formUserStatusRemark. This manipulation of the argument Username causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed a...

9CVSS0.00752EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
•added 2025/10/06 6:02 a.m.•5 views

CVE-2025-11323 UTT 1250GW formUserStatusRemark strcpy buffer overflow

A vulnerability was determined in UTT 1250GW up to v2v3.2.2-200710. Affected is the function strcpy of the file /goform/formUserStatusRemark. This manipulation of the argument Username causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed a...

9CVSS7.8AI score0.00752EPSS
SaveExploits1References4
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•21 views

PT-2025-40857

Name of the Vulnerable Software and Affected Versions Tenda AC18 version 15.03.05.196318 Description A security issue exists in Tenda AC18 routers. A stack-based buffer overflow can occur due to manipulation of the Username argument within the /goform/fast setting pppoe set file. This issue is...

9CVSS9.1AI score0.00799EPSS
SaveExploits1References12
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•22 views

PT-2025-40866

Name of the Vulnerable Software and Affected Versions affected versions not specified Description The application reveals whether a username exists during failed login attempts by returning different error messages for incorrect passwords versus non-existent usernames. This enables an attacker to...

5.3CVSS6.4AI score0.00364EPSS
SaveExploits0References9
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•11 views

PT-2025-40939

Name of the Vulnerable Software and Affected Versions OpenSSH versions prior to 10.1 Alma Linux affected versions not specified SUSE affected versions not specified IBM AIX affected versions not specified Fortinet FortiWeb affected versions not specified Description OpenSSH before version 10.1...

3.6CVSS7.4AI score0.00452EPSS
SaveExploits2References151
CNNVD
CNNVD
•added 2025/10/06 12:00 a.m.•22 views

Tenda AC18 安全漏洞

Tenda AC18 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in July 2016, mainly for villas and large home users. Tenda AC18 has a stack buffer overflow vulnerability, which originates from the parameter Username in the file /goform/fastsettingpppoeset fails to...

9CVSS8.3AI score0.00799EPSS
SaveExploits1References5
Vulnrichment
Vulnrichment
•added 2025/10/06 12:00 a.m.•3 views

CVE-2025-61984

ssh in OpenSSH before 10.1 allows control characters in usernames that originate from certain possibly untrusted sources, potentially leading to code execution when a ProxyCommand is used. The untrusted sources are the command line and %-sequence expansion of a configuration file. A configuration...

3.6CVSS6.7AI score0.00452EPSS
SaveExploits2References3
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•27 views

PT-2025-40863

Name of the Vulnerable Software and Affected Versions The product name cannot be determined. affected versions not specified Description The application provides access to a login-protected H2 database used for caching. The username is prefilled, potentially allowing unauthorized access if defaul...

5.3CVSS6.4AI score0.00364EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•29 views

PT-2025-40864

Name of the Vulnerable Software and Affected Versions affected versions not specified Description The username and password are sent directly in the URL as parameters within HTTP requests. This practice poses a significant risk of sensitive data disclosure, as URLs may be stored in server logs,...

5.3CVSS6.3AI score0.00389EPSS
SaveExploits0References8
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/06 12:00 a.m.•11 views

CVE-2025-58586: Observable Response Discrepancy

For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a non-existing username. This allows an attacker to guess usernames until they find an existing one...

5.3CVSS5.8AI score0.00364EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/10/06 12:00 a.m.•19 views

SICK AG Baggage Analytics 安全漏洞

SICK AG Baggage Analytics is a visualization and analysis software for airport tracking systems from SICK AG, Germany. A security vulnerability exists in SICK AG Baggage Analytics that stems from a different error message being returned on login failure, which could lead to a username enumeration...

5.3CVSS6.6AI score0.00364EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•30 views

PT-2025-40852

Name of the Vulnerable Software and Affected Versions UTT versions prior to v2v3.2.2-200710 Description A buffer overflow issue exists in the strcpy function within the /goform/formUserStatusRemark file. Manipulation of the Username argument can trigger this issue, potentially allowing for remote...

9CVSS9AI score0.00752EPSS
SaveExploits1References9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/06 12:00 a.m.•4 views

CVE-2025-11325: Stack-based Buffer Overflow

A security flaw has been discovered in Tenda AC18 15.03.05.196318. Affected by this issue is some unknown functionality of the file /goform/fastsettingpppoeset. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out...

9CVSS8.2AI score0.00799EPSS
SaveExploits1References6
CVE
CVE
•added 2025/10/06 12:00 a.m.•1810 views

CVE-2025-61984

CVE-2025-61984 affects OpenSSH before 10.1. It allows control characters in usernames originating from untrusted sources (command line or %-sequence expansion in a config file), potentially enabling code execution when a ProxyCommand is used. A config file that provides a complete literal usernam...

3.6CVSS6.7AI score0.00452EPSS
SaveExploits2References10
CNNVD
CNNVD
•added 2025/10/06 12:00 a.m.•32 views

UTT 1250GW 安全漏洞

The UTT 1250GW is a wireless router from China Aitai UTT. A security vulnerability exists in UTT 1250GW v2v3.2.2-200710 and earlier versions, which stems from an incorrect manipulation of the parameter Username in the file /goform/formUserStatusRemark, which could result in a buffer overflow...

9CVSS8.9AI score0.00752EPSS
SaveExploits1References4
AlpineLinux
AlpineLinux
•added 2025/10/06 12:00 a.m.•28 views

CVE-2025-61984

ssh in OpenSSH before 10.1 allows control characters in usernames that originate from certain possibly untrusted sources, potentially leading to code execution when a ProxyCommand is used. The untrusted sources are the command line and %-sequence expansion of a configuration file. A configuration...

3.6CVSS6.7AI score0.00452EPSS
SaveExploits2References10
osv_cve
osv_cve
•added 2025/10/05 5:15 p.m.•17 views

CVE-2025-11295

A flaw has been found in Belkin F9K1015 1.00.10. This affects an unknown part of the file /goform/formPPPoESetup. This manipulation of the argument pppUserName causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was...

8.7CVSS5.9AI score0.01087EPSS
SaveExploits1References5
NVD
NVD
•added 2025/10/05 4:15 p.m.•20 views

CVE-2025-11294

A vulnerability was detected in Belkin F9K1015 1.00.10. Affected by this issue is some unknown functionality of the file /goform/formL2TPSetup. The manipulation of the argument L2TPUserName results in buffer overflow. The attack may be launched remotely. The exploit is now public and may be used...

9CVSS0.01307EPSS
SaveExploits1References5
CNNVD
CNNVD
•added 2025/10/05 12:00 a.m.•24 views

Belkin F9K1015 安全漏洞

Belkin F9K1015 is a WiFi signal extender from Belkin Canada. A security vulnerability exists in the Belkin F9K1015 version 1.00.10, which stems from incorrect manipulation of the parameter L2TPUserName in the file /goform/formL2TPSetup, which could result in a buffer overflow...

9CVSS9AI score0.01307EPSS
SaveExploits1References5
Rows per page
Query Builder