12 matches found
CVE-2026-76105
Dell Container Storage Modules, versions prior to 1.18.0 contains an Use of Insufficiently Random Values vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information tampering...
CVE-2026-66391
Use of Insufficiently Random Values, Protection Mechanism Failure vulnerability in Apache Wicket. This issue affects Apache Wicket: from 9.0.0 through 9.23.0, from 10.0.0 through 10.9.0. Users are recommended to upgrade to version 10.10.0, which fixes the issue...
CVE-2024-36389
MileSight DeviceHub - CWE-330 Use of Insufficiently Random Values may allow Authentication Bypass...
CVE-2024-28013: Use of Insufficiently Random Values
Use of Insufficiently Random Values vulnerability in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX-MS, WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP,...
Honeywell OneWireless Wireless Device Manager
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Honeywell Equipment: OneWireless Wireless Device Manager WDM Vulnerabilities: Command Injection, Use of Insufficiently Random Values, Missing Authentication for Critical Function 2. RISK EVALUATION...
ABB Pulsar Plus Controller
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: Pulsar Plus Controller Vulnerabilities: Use of Insufficiently Random Values, Cross-Site Request Forgery CSRF 2. RISK EVALUATION Successful exploitation of these vulnerabilities could...
CVE-2023-22601: Use of Insufficiently Random Values
InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-330: Use of Insufficiently Random Values. They do not properly randomize MQTT ClientID parameters. An unauthorized user could calculate this...
CVE-2021-38606: Use of Insufficiently Random Values
reNgine through 0.5 relies on a predictable directory name...
CVE-2021-28674: Use of Insufficiently Random Values
The node management page in SolarWinds Orion Platform before 2020.2.5 HF1 allows an attacker to create or delete a node outside of the attacker's perimeter via an account with write permissions. This occurs because node IDs are predictable with incrementing numbers and the access control on...
Siemens Linux-based Products (Update J)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2020-7548
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways see security notification for version information that could allow unauthorized users to login...
PT-2017-16842
Name of the Vulnerable Software and Affected Versions Modicon M241 versions prior to 4.0.5.11 Modicon M251 versions prior to 4.0.5.11 Description A Use of Insufficiently Random Values issue was discovered, where the session numbers generated by the web application lack randomization and are share...