Lucene search
+L

11123 matches found

Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Emerson Deltav Unspecified Vulnerability

The Emerson DeltaV SE3006 through 11.3.1, DeltaV VE3005 through 10.3.1 and 11.x through 11.3.1, and DeltaV VE3006 through 10.3.1 and 11.x through 11.3.1 allow remote attackers to cause a denial of service device restart via a crafted packet on 1 TCP port 23, 2 UDP port 161, or 3 TCP port 513. Fil...

6.1CVSS4.9AI score0.00865EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.25 views

Enea Ose Unspecified Vulnerability

The Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier have hardcoded credentials in a ROM, which makes it easier for remote attackers to obtain shell access to the underlying OS by...

9CVSS4AI score0.02583EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.17 views

Rockwellautomation Connected Unspecified Vulnerability

Rockwell Automation Connected Components Workbench CCW before 7.00.00 allows remote attackers to cause a denial of service application crash or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler. File data ot500145.nasl...

7.5CVSS6.7AI score0.11EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.14 views

Siemens Simatic Unspecified Vulnerability

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. File data ot500265.nasl...

4.3CVSS5.2AI score0.02204EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.20 views

Siemens Simatic Unspecified Vulnerability

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. File data ot500262.nasl...

4.3CVSS5.3AI score0.01493EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.37 views

Schneider-electric Somachine Unspecified Vulnerability

An Incorrect Default Permissions CWE-276 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic. File...

5.5CVSS2.7AI score0.0031EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.21 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. File data ot500177.nasl...

6.1CVSS5.4AI score0.01253EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.26 views

Rockwellautomation Rsview32 Unspecified Vulnerability

Rockwell Automation RSView32 7.60.00 aka CPR9 SR4 and earlier does not properly encrypt credentials, which allows local users to obtain sensitive information by reading a file and conducting a decryption attack. File data ot500222.nasl...

4.9CVSS3.5AI score0.00615EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Schneider-electric Modicon Unspecified Vulnerability

In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. File data ot500069.nasl...

6.4CVSS5AI score0.01399EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Siemens Sicam Unspecified Vulnerability

An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database. File data ot500097.nasl...

4.6CVSS3.6AI score0.00317EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.28 views

Siemens Eta4 Unspecified Vulnerability

An issue was discovered in Siemens ETA4 firmware all versions prior to Revision 08 of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start migh...

7.8CVSS3.4AI score0.02052EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255. File data ot500112.nasl...

7.8CVSS4.9AI score0.04642EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.37 views

Rockwellautomation Ab Unspecified Vulnerability

Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits. File data...

7.1CVSS5AI score0.0405EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.26 views

Schneider-electric Modicon Unspecified Vulnerability

The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests...

8.5CVSS4.7AI score0.03909EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Rockwellautomation Micrologix Unspecified Vulnerability

An exploitable denial of service vulnerability exists in the program download functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a device fault resulting in halted operations. An attacker can send an unauthenticated packet to trigger...

7.8CVSS2.7AI score0.04662EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.19 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets. File data ot500037.nasl...

7.8CVSS5.1AI score0.04456EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.18 views

Siemens Simatic Unspecified Vulnerability

The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors. File data ot500178.nasl...

5.8CVSS5.7AI score0.02417EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.28 views

Siemens Simatic Unspecified Vulnerability

The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...

8.3CVSS5.1AI score0.03156EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259. File data ot500184.nasl...

7.8CVSS4.8AI score0.04642EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.18 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257. File data ot500263.nasl...

7.8CVSS5.6AI score0.03609EPSS
SaveExploits1References4
Rows per page