472 matches found
CVE-2025-62472
Use of uninitialized resource in Windows Remote Access Connection Manager allows an authorized attacker to elevate privileges locally...
EUVD-2025-202248
Use of uninitialized resource in Windows Remote Access Connection Manager allows an authorized attacker to elevate privileges locally...
Windows Remote Access Connection Manager Elevation of Privilege Vulnerability
Use of uninitialized resource in Windows Remote Access Connection Manager allows an authorized attacker to elevate privileges locally...
PT-2025-50171
Name of the Vulnerable Software and Affected Versions Windows Remote Access Connection Manager affected versions not specified Description The Windows Remote Access Connection Manager contains a flaw involving the use of an uninitialized resource. This can allow a local attacker to gain elevated...
ROS-20251201-02
A vulnerability in the vfsinode.c component of the Linux kernel is related to the use of an uninitialized resource. of an uninitialized resource. Exploitation of the vulnerability could allow an attacker to cause a denial of denial of service A vulnerability in the llcpsock.c component of the Lin...
Siemens SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-50273)
btrfs: reinitialize delayed ref list after deleting it from the list. At insertdelayedref if there is a need to update the action of an existing ref to BTRFSDROPDELAYEDREF, the ref from its ref head's refaddlist is deleted using listdel, which leaves the ref's addlist member not reinitialized, as...
Siemens SIMATIC S7-1500 Use of Uninitialized Resource (CVE-2024-42106)
In the Linux kernel, the following vulnerability has been resolved: inetdiag: Initialize pad field in struct inetdiagreqv2. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-26863)
In the Linux kernel, the following vulnerability has been resolved: hsr: Fix uninit-value access in hsrgetnode. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-46865)
In the Linux kernel, the following vulnerability has been resolved: fou: fix initialization of grc The grc must be initialize first. There can be a condition where if fou is NULL, goto out will be executed and grc would be used uninitialized. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-35950)
drm/client: Fully protect modes with dev-modeconfig.mutex This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503496; scriptversion"1.2";...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2025-21787)
team: better TEAMOPTIONTYPESTRING validation This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503529; scriptversion"1.2";...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-35849)
In the Linux kernel, the following vulnerability has been resolved: btrfs: fix information leak in btrfsioctllogicaltoino This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc';...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-49900)
In the Linux kernel, the following vulnerability has been resolved: jfs: Fix uninit-value access of newea in eabuffer syzbot reports that lzo1x1docompress is using uninit-value: ===================================================== BUG: KMSAN: uninit-value in lzo1x1docompress+0x19f9/0x2510...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-46744)
In the Linux kernel, the following vulnerability has been resolved: Squashfs: sanity check symbolic link size. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2025-21862)
dropmonitor: incorrect initialization order. If dropmonitor is built as a kernel module, syzkaller may have time to send a netlink NETDMCMDSTART message during the module loading. This will call the netdmmonitorstart function that uses a spinlock that has not yet been initialized. This plugin onl...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-26920)
In the Linux kernel, the following vulnerability has been resolved: tracing/trigger: Fix to return error if failed to alloc snapshot This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-50033)
In the Linux kernel, the following vulnerability has been resolved: slip: make slhcremember more robust against malicious packets syzbot found that slhcremember was missing checks against malicious packets 1. slhcremember only checked the size of the packet was at least 20, which is not good...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-35893)
In the Linux kernel, the following vulnerability has been resolved: net/sched: actskbmod: prevent kernel-infoleak syzbot found that tcfskbmoddump was copying four bytes from kernel stack to user space. The issue here is that 'struct tcskbmod' has a four bytes hole. We need to clear the structure...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-35973)
geneve: fix header validation in genevexmitskb This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503444; scriptversion"1.2";...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-50035)
In the Linux kernel, the following vulnerability has been resolved: ppp: fix pppasyncencode illegal access syzbot reported an issue in pppasyncencode 1 In this case, pppoesendmsg is called with a zero size. Then pppasyncencode is called with an empty skb. BUG: KMSAN: uninit-value in pppasyncencod...