CVE-2016-9354
An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption...
CVE-2016-8374
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen...
Design/Logic Flaw
An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption...
CVE-2016-8374
CVE-2016-8374 affects Schneider Electric Magelis HMI panels (GTO, GTU, STO/STU, XBT lines) where the Web Gate Server Web UI can be overwhelmed, causing UNCONTROLLED RESOURCE CONSUMPTION and denial of service. Root cause is improper handling of HTTP requests leading to resource exhaustion; exploit...
Exploit for Uncontrolled Resource Consumption in Openssl
CVE-2016-8610 PoC CVE-2016-8610 SSL Death Alert PoC Usage:...
PT-2016-3004 · Qemu +3 · Qemu +3
Name of the Vulnerable Software and Affected Versions: QEMU affected versions not specified Description: The issue is related to an uncontrolled resource consumption in the Virtio GPU emulator hardware of QEMU. It may allow a local attacker to compromise the confidentiality, integrity, and...
SAP SQL Anywhere MobiLink Synchronization Server - buffer overflow vulnerability
Application: SAP SQL Anywhere MobiLink Synchronization Server 17 Vendor URL: SAP Bug: Buffer overflow Reported: 01.02.2016 Vendor response: 02.02.2016 Date of Public Advisory: 14.06.2016 Reference: SAP Security Note 2308778 Author: Vahagn VardanyanERPScan VULNERABILITY INFORMATION Class: Buffer...
Hospira Plum A+ and Symbiq Infusion Systems Vulnerabilities
OVERVIEW Independent researcher Billy Rios has identified vulnerabilities in Hospira’s Plum A+ Infusion System that are similar to vulnerabilities identified in Hospira’s LifeCare PCA Infusion System discussed in advisory, ICSA-15-125-01B Hospira LifeCare PCA Infusion System Vulnerabilities...
MGASA-2014-0537 Updated file packages fix security vulnerabilities
Updated file packages fix security vulnerabilities: Thomas Jarosch of Intra2net AG reported that using the file command on a specially-crafted ELF binary could lead to a denial of service due to uncontrolled resource consumption CVE-2014-8116. Thomas Jarosch of Intra2net AG reported that using th...
Siemens RuggedCom Uncontrolled Resource Consumption Vulnerability (Update B)
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-14-051-03A Siemens RuggedCom Uncontrolled Resource Consumption Vulnerability that was published March 18, 2014, on the NCCIC/ICS-CERT web site. Researchers Ling Toh Koh, Ng Yi Teng, Seyed Dawood Sajjadi Torshizi, Ry...
Schneider Electric ClearSCADA Uncontrolled Resource Consumption Vulnerability
OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an uncontrolled resource consumption vulnerability in the Schneider Electric SCADA Expert ClearSCADA software. Schneider Electric has produced a new version that mitigates this vulnerability. Adam Crain has...
Triangle MicroWorks Uncontrolled Resource Consumption
OVERVIEW Adam Crain of Automatak and Chris Sistrunk of Mandiant have identified an uncontrolled resource consumption vulnerability in Triangle MicroWorks products and third-party components. Triangle MicroWorks has produced an update that mitigates this vulnerability. This vulnerability could be...
ASUS AiCloud Enabled Routers 12 Models - Authentication bypass and Sensitive file/path disclosure
ASUS routers, which are enabled with the AiCloud service SSL ports, are vulnerable to bypass of authentication and sensitive file disclosure. This vulnerability has been observed in all firmware versions, though the latest version increases the complexity of the attack. By sending a special craft...
DHS Warns of Schneider Electric ClearSCADA Vulnerability
The Department of Homeland Security is warning the maintainers of industrial control systems ICS about a remotely exploitable uncontrolled resource consumption vulnerability in Schneider Electric’s ClearSCADA software. Schneider Electric says that it has developed a new version of ClearSCADA that...