Lucene search
+L

134 matches found

NVD
NVD
added 2021/01/05 11:15 p.m.30 views

CVE-2020-7336

Cross Site Request Forgery vulnerability in McAfee Network Security Management NSM prior to 10.1.7.35 and NSM 9.x prior to 9.2.9.55 may allow an attacker to change the configuration of the Network Security Manager via a carefully crafted HTTP request...

6.6CVSS6.4AI score0.00523EPSS
SaveExploits0References1
NVD
NVD
added 2020/04/08 8:15 p.m.27 views

CVE-2020-1630

A privilege escalation vulnerability in Juniper Networks Junos OS devices configured with dual Routing Engines RE, Virtual Chassis VC or high-availability cluster may allow a local authenticated low-privileged user with access to the shell to perform unauthorized configuration modification. This...

5.5CVSS5.3AI score0.00221EPSS
SaveExploits0References1
Prion
Prion
added 2020/04/08 8:15 p.m.21 views

Privilege escalation

A privilege escalation vulnerability in Juniper Networks Junos OS devices configured with dual Routing Engines RE, Virtual Chassis VC or high-availability cluster may allow a local authenticated low-privileged user with access to the shell to perform unauthorized configuration modification. This...

2.1CVSS5.7AI score0.00221EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/04/08 7:26 p.m.36 views

CVE-2020-1630 Junos OS: Privilege escalation vulnerability in dual REs, VC or HA cluster may allow unauthorized configuration change.

A privilege escalation vulnerability in Juniper Networks Junos OS devices configured with dual Routing Engines RE, Virtual Chassis VC or high-availability cluster may allow a local authenticated low-privileged user with access to the shell to perform unauthorized configuration modification. This...

5CVSS5.6AI score0.00221EPSS
SaveExploits0References1
Prion
Prion
added 2019/12/23 6:15 p.m.28 views

Design/Logic Flaw

On BIG-IP versions 15.0.0-15.0.1, 14.1.0.2-14.1.2.2, 14.0.0.5-14.0.1, 13.1.1.5-13.1.3.1, 12.1.4.1-12.1.5, 11.6.4-11.6.5, and 11.5.9-11.5.10, the access controls implemented by scp.whitelist and scp.blacklist are not properly enforced for paths that are symlinks. This allows authenticated users wi...

3.6CVSS4AI score0.00308EPSS
SaveExploits0References1Affected Software13
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.39 views

Siemens Siprotec Missing Authentication for Critical Function

A vulnerability has been identified in Siemens DIGSI 4 All versions V4.92, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module PROFINET IO variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module DNP3 variant All versions,...

5CVSS4AI score0.01777EPSS
SaveExploits0References3
Prion
Prion
added 2019/10/25 6:15 p.m.17 views

Authentication flaw

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on an...

5CVSS8.1AI score0.01035EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
added 2019/10/25 5:43 p.m.57 views

CVE-2019-13549

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on an...

7.7AI score0.01035EPSS
SaveExploits1References2
CVE
CVE
added 2019/10/25 5:43 p.m.198 views

CVE-2019-13549

CVE-2019-13549 affects the Rittal Chiller SK 3232-Series web interface built on Carel pCOWeb firmware A1.5.3–B1.2.4. The issue is improper access control: authentication does not sufficiently protect against unauthorized configuration changes, allowing modification of primary operations (turning ...

7.5CVSS7.6AI score0.01035EPSS
SaveExploits1References2Affected Software1
NVD
NVD
added 2019/03/26 4:29 p.m.21 views

CVE-2014-5432

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...

9.8CVSS9.6AI score0.02573EPSS
SaveExploits0References1
Prion
Prion
added 2019/03/26 4:29 p.m.26 views

Command injection

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...

7.5CVSS7.3AI score0.02573EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/03/26 3:17 p.m.28 views

CVE-2014-5432

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...

9.6AI score0.02573EPSS
SaveExploits0References1
NVD
NVD
added 2019/01/22 3:29 p.m.25 views

CVE-2018-14666

An improper authorization flaw was found in the Smart Class feature of Foreman. An attacker can use it to change configuration of any host registered in Red Hat Satellite, independent of the organization the host belongs to. This flaw affects all Red Hat Satellite 6 versions...

7.2CVSS6.7AI score0.01047EPSS
SaveExploits0References2
Prion
Prion
added 2018/01/23 3:29 p.m.14 views

Design/Logic Flaw

When api-config-dir is set to a non-empty value, which is not the case by default, the API in PowerDNS Recursor 4.x up to and including 4.0.6 and 3.x up to and including 3.7.4 allows an authorized user to update the Recursor's ACL by adding and removing netmasks, and to configure forward zones. I...

3.5CVSS5.2AI score0.00828EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2017/05/29 4:29 p.m.13 views

CVE-2017-7917

A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell...

8.8CVSS5.8AI score0.00494EPSS
SaveExploits0References1
Prion
Prion
added 2017/03/15 8:59 p.m.27 views

Authentication flaw

A vulnerability in the web-based GUI of Cisco Mobility Express 1800 Series Access Points could allow an unauthenticated, remote attacker to bypass authentication. The attacker could be granted full administrator privileges. The vulnerability is due to improper implementation of authentication for...

10CVSS9.5AI score0.05275EPSS
SaveExploits0References2Affected Software1
NVD
NVD
added 2017/03/15 8:59 p.m.26 views

CVE-2017-3831

A vulnerability in the web-based GUI of Cisco Mobility Express 1800 Series Access Points could allow an unauthenticated, remote attacker to bypass authentication. The attacker could be granted full administrator privileges. The vulnerability is due to improper implementation of authentication for...

10CVSS9.7AI score0.05275EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2017/03/15 8:00 p.m.35 views

CVE-2017-3831

A vulnerability in the web-based GUI of Cisco Mobility Express 1800 Series Access Points could allow an unauthenticated, remote attacker to bypass authentication. The attacker could be granted full administrator privileges. The vulnerability is due to improper implementation of authentication for...

9.8AI score0.05275EPSS
SaveExploits0References2
Prion
Prion
added 2017/02/13 9:59 p.m.13 views

Cross site request forgery (csrf)

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability ca...

6.8CVSS7AI score0.02045EPSS
SaveExploits4References3
CVE
CVE
added 2017/02/13 9:00 p.m.72 views

CVE-2016-5809

Schneider Electric IONXXXX Series Power Meters (ION73XX, ION75XX, ION76XX, ION8650, ION8800, PM5XXX) are affected by CVE-2016-5809 due to lack of a CSRF token during sessions. This enables unauthorized configuration changes to be made and saved. Public materials (e.g., Exploit-DB, Packet Storm, T...

8.8CVSS8.4AI score0.02045EPSS
SaveExploits4References3Affected Software6
Rows per page
Query Builder