Lucene search
+L

685 matches found

NVD
NVD
added 2024/11/14 10:15 p.m.14 views

CVE-2024-48974

The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This...

9.3CVSS0.00154EPSS
SaveExploits0References1
NVD
NVD
added 2024/11/14 10:15 p.m.23 views

CVE-2024-48967

The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings...

10CVSS0.0063EPSS
SaveExploits0References1
CVE
CVE
added 2024/11/14 9:40 p.m.59 views

CVE-2024-48967

The CVE-2024-48967 entry concerns Baxter Life2000 ventilator and associated Service PC, where inadequate audit logging prevents detection of malicious activity. The description states that an attacker with access could alter ventilator settings without detection, leading to unauthorized informati...

10CVSS9AI score0.0063EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/11/14 9:40 p.m.35 views

CVE-2024-48967 Life2000 ventilator and Service PC lack sufficient audit logging capabilities

The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings...

10CVSS0.0063EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/11/14 9:40 p.m.19 views

CVE-2024-48967 Life2000 ventilator and Service PC lack sufficient audit logging capabilities

The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings...

10CVSS6.5AI score0.0063EPSS
SaveExploits0References1
CVE
CVE
added 2024/11/14 9:27 p.m.65 views

CVE-2024-48974

The CVE-2024-48974 entry concerns Baxter Life2000 ventilators, where the firmware update process does not perform proper file integrity checks on the update file. The underlying consequence is that an attacker could push a compromised or illegitimate firmware image, enabling unauthorized changes ...

9.3CVSS8.9AI score0.00154EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/11/14 9:27 p.m.17 views

CVE-2024-48974 Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates

The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This...

9.3CVSS6.4AI score0.00154EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/11/14 9:27 p.m.34 views

CVE-2024-48974 Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates

The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This...

9.3CVSS0.00154EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2024/11/14 11:50 a.m.51 views

CVE-2024-45670 IBM Security SOAR weak password recovery mechanism

IBM Security SOAR 51.0.1.0 and earlier contains a mechanism for users to recover or change their passwords without knowing the original password, but the user account must be compromised prior to the weak recovery mechanism...

5.6CVSS0.00328EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2024/11/14 12:00 a.m.13 views

PT-2024-33308 · Unknown · Ventilator

Name of the Vulnerable Software and Affected Versions: Ventilator affected versions not specified Description: The issue concerns the ventilator's failure to perform proper file integrity checks when adopting firmware updates. This allows an attacker to force unauthorized changes to the device's...

9.3CVSS6.5AI score0.00154EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2024/11/14 12:00 a.m.12 views

PT-2024-33303 · Unknown · Service Pc +1

Name of the Vulnerable Software and Affected Versions: Ventilator and Service PC affected versions not specified Description: The ventilator and the Service PC lack sufficient audit logging capabilities, making it difficult to detect malicious activity and conduct forensic examinations. An attack...

10CVSS6.4AI score0.0063EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2024/10/29 12:00 a.m.14 views

PT-2024-16282 · WordPress · Wpc Smart Messages

Name of the Vulnerable Software and Affected Versions: WPC Smart Messages for WooCommerce plugin for WordPress versions up to, and including, 4.2.1 Description: The issue allows authenticated attackers with Subscriber-level access and above to activate or deactivate smart messages due to a missin...

4.3CVSS6.7AI score0.00363EPSS
SaveExploits0References6
Debian CVE
Debian CVE
added 2024/10/21 11:53 a.m.14 views

CVE-2024-47701

In the Linux kernel, the following vulnerability has been resolved: ext4: avoid OOB when system.data xattr changes underneath the filesystem When looking up for an entry in an inlined directory, if evalueoffs is changed underneath the filesystem by some change in the block device, it will lead to...

7.8CVSS6AI score0.00247EPSS
SaveExploits0
Positive Technologies
Positive Technologies
added 2024/10/09 12:00 a.m.16 views

PT-2024-39065 · WordPress · Qa Analytics – Web Analytics Tool With Heatmaps & Session Replay Across All Pages

Name of the Vulnerable Software and Affected Versions: QA Analytics – Web Analytics Tool with Heatmaps & Session Replay Across All Pages plugin for WordPress versions up to, and including, 4.1.0.0 Description: The issue is related to a missing capability check on the ajax save plugin config...

5.3CVSS6.8AI score0.00423EPSS
SaveExploits0References8
CNNVD
CNNVD
added 2024/10/01 12:00 a.m.9 views

WordPress plugin KB Support 安全漏洞

WordPress and WordPress plugin are products of the WordPress Foundation, a blogging platform developed in the PHP language. The platform supports personal blog sites on PHP and MySQL servers.WordPress plugin is an application plugin. A security vulnerability exists in WordPress plugin KB Support...

8.1CVSS6.4AI score0.00363EPSS
SaveExploits0References14
CVE
CVE
added 2024/09/17 6:00 a.m.59 views

CVE-2024-8093

The CVE-2024-8093 entry concerns the WordPress plugin “Posts reminder” (versions

6.5CVSS6.3AI score0.00189EPSS
SaveExploits1References1Affected Software1
Veracode
Veracode
added 2024/09/09 12:04 p.m.7 views

Improper Input Validation

github.com/cosmos/interchain-security is vulnerable to Improper Input Validation. The vulnerability is caused due to a missing validation on the ICS side to check if the signer matches the provider address. This can lead to any user opt-in, opt-out, change the commission rate, or change what publ...

7AI score
SaveExploits0References1Affected Software1
OSV
OSV
added 2024/08/27 4:15 p.m.7 views

CVE-2024-8199

The Reviews Feed – Add Testimonials and Customer Reviews From Google Reviews, Yelp, TripAdvisor, and More plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the 'updateapikey' function in all versions up to, and including, 1.1.2. This make...

4.3CVSS5.8AI score0.00401EPSS
SaveExploits0References3
CNVD
CNVD
added 2024/08/14 12:00 a.m.20 views

Siemens SINEC NMS Authorization Error Vulnerability (CNVD-2024-35422)

SINEC NMS is a new generation network management system for digital enterprises. An authorization error vulnerability exists in Siemens SINEC NMS, which can be exploited by an authenticated attacker to bypass checks and make unauthorized changes to settings in the application...

5.3CVSS6.6AI score0.0026EPSS
SaveExploits0References1
NVD
NVD
added 2024/08/02 5:15 a.m.47 views

CVE-2024-7389

The Forminator plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 1.29.1 via class-forminator-addon-hubspot-wp-api.php. This makes it possible for unauthenticated attackers to extract the HubSpot integration developer API key and make...

7.5CVSS0.00658EPSS
SaveExploits1References5