2710 matches found
CVE-2019-11177
Unhandled exception in IntelR Baseboard Management Controller firmware may allow an unauthenticated user to potentially enable denial of service via network access...
CVE-2019-11173
Insufficient session validation in IntelR Baseboard Management Controller firmware may allow an unauthenticated user to potentially enable information disclosure and/or denial of service via local access...
CVE-2019-11171
Heap corruption in IntelR Baseboard Management Controller firmware may allow an unauthenticated user to potentially enable information disclosure, escalation of privilege and/or denial of service via network access...
GHSA-FM68-89M8-4GJJ Composer JavaScript injection possible via html comments
In Magento 2.2 prior to 2.2.10, Magento 2.3 prior to 2.3.3 or 2.3.2-p1, an unauthenticated user can inject arbitrary JavaScript code as a result of the sanitization engine ignoring HTML comments...
CVE-2019-12719
An issue was discovered in PictureManagemvc.aspx in AUO SunVeillance Monitoring System before v1.1.9e. There is an incorrect access control vulnerability that can allow an unauthenticated user to upload files via a modified authority parameter...
Improper access control
An issue was discovered in PictureManagemvc.aspx in AUO SunVeillance Monitoring System before v1.1.9e. There is an incorrect access control vulnerability that can allow an unauthenticated user to upload files via a modified authority parameter...
Design/Logic Flaw
A vulnerability in Hitachi Command Suite 7.x and 8.x before 8.7.0-00 allows an unauthenticated remote user to trigger a denial of service DoS condition because of Uncontrolled Resource Consumption...
CVE-2018-21026
A vulnerability in Hitachi Command Suite 7.x and 8.x before 8.6.5-00 allows an unauthenticated remote user to read internal information...
CVE-2019-18623
Escalation of privileges in EnergyCAP 7 through 7.5.6 allows an attacker to access data. If an unauthenticated user clicks on a link on the public dashboard, the resource opens in EnergyCAP with access rights matching the user who created the dashboard...
Updated proftpd packages fix security vulnerabilities
Updated proftpd package fixes security vulnerabilities: It was discovered that the modcopy module of ProFTPD, a FTP/SFTP/FTPS server, performed incomplete permission validation for the CPFR/CPTO commands CVE-2019-12815. It was discovered that due to incorrect handling of overly long commands, a...
CVE-2019-5617
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user...
CVE-2019-5643
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation...
CVE-2019-5644
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator...
Improper access control
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user...
Improper access control
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation...
Improper access control
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator...
CVE-2019-5644 C4G BLIS Improper Access Control
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator...
CVE-2019-5643 C4G BLIS Improper Access Control
Computing For Good's Basic Laboratory Information System also known as C4G BLIS version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation...
CVE-2019-5617 C4G BLIS Improper Access Control