Lucene search
+L

8 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/04/10 12:00 a.m.•9 views

CVE-2019-5426: Improper Authentication

In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, an unauthenticated user can use the "local port forwarding" and "dynamic port forwarding" SOCKS proxy functionalities. Remote attackers without credentials can exploit this bug to access local services or forward traffic through the device if SS...

5.8CVSS5.8AI score0.00809EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/04/10 12:00 a.m.•11 views

CVE-2019-5425: Improper Neutralization of Special Elements used in an OS Command

In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, an authenticated user can execute arbitrary shell commands over the SSH interface bypassing the CLI interface, which allow them to escalate privileges to root...

9CVSS6.2AI score0.01906EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/04/10 12:00 a.m.•13 views

CVE-2019-5424: Improper Neutralization of Special Elements used in a Command

In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user...

9CVSS6.2AI score0.01904EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2018/06/20 12:00 p.m.•37 views

CVE-2018-12591

Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admi...

7.7AI score0.01861EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/06/20 12:00 a.m.•7 views

CVE-2018-12591: Improper Neutralization of Special Elements used in an OS Command

Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admi...

9CVSS7.8AI score0.01861EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/06/20 12:00 a.m.•12 views

CVE-2018-12590: Use of Externally-Controlled Format String

Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an...

9CVSS7.9AI score0.0167EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2018/06/20 12:00 a.m.•6 views

PT-2018-11277

Name of the Vulnerable Software and Affected Versions Ubiquiti Networks EdgeSwitch versions 1.7.3 and prior Description The issue arises from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation. An...

9CVSS0.01861EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2018/06/20 12:00 a.m.•10 views

PT-2018-11276

Name of the Vulnerable Software and Affected Versions Ubiquiti Networks EdgeSwitch versions 1.7.3 and prior Description The issue is an externally controlled format-string vulnerability due to lack of protection on the admin CLI. This vulnerability can lead to code execution and privilege...

9CVSS0.0167EPSS
SaveExploits0References3
Rows per page
Query Builder