Lucene search
+L

159 matches found

NVD
NVD
•added 2025/03/10 9:15 a.m.•16 views

CVE-2025-27257

Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware. The firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration che...

6.1CVSS0.00181EPSS
SaveExploits0References2
NVD
NVD
•added 2025/03/10 9:15 a.m.•19 views

CVE-2025-27256

Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network...

8.3CVSS0.00283EPSS
SaveExploits0References2
NVD
NVD
•added 2025/03/10 9:15 a.m.•19 views

CVE-2025-27253

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to...

6.1CVSS0.00234EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
•added 2025/03/10 9:05 a.m.•6 views

CVE-2025-27256

Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network...

8.3CVSS7AI score0.00283EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2025/03/10 9:05 a.m.•33 views

CVE-2025-27255

Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code...

8CVSS0.00152EPSS
SaveExploits0References2
CVE
CVE
•added 2025/03/10 9:05 a.m.•116 views

CVE-2025-27255

This CVE concerns GE Vernova EnerVista UR Setup. The vulnerability arises from hard-coded credentials used to encrypt the local user database, with the credential password retrievable by analyzing the application code. A local attacker could leverage this to escalate privileges on the affected sy...

8CVSS7.2AI score0.00152EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2025/03/10 12:00 a.m.•9 views

GE Vernova EnerVista UR 访问控制错误漏洞

GE Vernova EnerVista UR is a device configuration tool from GE Vernova USA that is compatible with all UR relay applications. An access control error vulnerability exists in the GE Vernova EnerVista UR that stems from a lack of critical function authentication, which could lead to authentication...

8.3CVSS6.9AI score0.00283EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/10 12:00 a.m.•5 views

CVE-2025-27256: Missing Authentication for Critical Function

Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network...

8.3CVSS7.6AI score0.00283EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/03/10 12:00 a.m.•7 views

PT-2025-10564

Name of the Vulnerable Software and Affected Versions GE Vernova UR IED family devices versions 7.0 through 8.60 Description The issue is related to improper input validation, which allows an attacker to establish a TCP connection through port forwarding. This lack of validation for IP addresses...

6.1CVSS0.00234EPSS
SaveExploits0References11
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/10 12:00 a.m.•6 views

CVE-2025-27253: External Control of System or Configuration Setting

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to...

6.1CVSS6.2AI score0.00234EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/03/10 12:00 a.m.•6 views

PT-2025-10566

Name of the Vulnerable Software and Affected Versions GE Vernova EnerVista UR Setup affected versions not specified Description The issue concerns the use of hard-coded credentials in the software, allowing privilege escalation. An attacker can retrieve the hardcoded password by analyzing the...

8CVSS0.00152EPSS
SaveExploits0References15
Positive Technologies
Positive Technologies
•added 2025/03/10 12:00 a.m.•2 views

PT-2025-10565

Name of the Vulnerable Software and Affected Versions GE Vernova EnerVista UR Setup affected versions not specified Description The issue concerns an improper authentication vulnerability that allows authentication bypass. It is possible to disable the software's startup authentication by modifyi...

8CVSS0.00188EPSS
SaveExploits0References17
Positive Technologies
Positive Technologies
•added 2025/03/10 12:00 a.m.•7 views

PT-2025-10568

Name of the Vulnerable Software and Affected Versions GE Vernova UR IED family devices affected versions not specified Description The issue concerns an Insufficient Verification of Data Authenticity, which enables an authenticated user to install modified firmware. This is possible because...

6.1CVSS0.00181EPSS
SaveExploits0References11
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/10 12:00 a.m.•8 views

CVE-2025-27257: Insufficient Verification of Data Authenticity

Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware. The firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration che...

6.1CVSS6.3AI score0.00181EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/10 12:00 a.m.•5 views

CVE-2025-27254: Improper Ownership Management

CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass. The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify...

8CVSS7.5AI score0.00188EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/03/10 12:00 a.m.•7 views

PT-2025-10567

Name of the Vulnerable Software and Affected Versions GE Vernova Enervista UR Setup affected versions not specified Description The issue concerns a Missing Authentication for Critical Function vulnerability. It allows for Authentication Bypass due to a missing SSH server authentication, enabling...

8.3CVSS0.00283EPSS
SaveExploits0References17
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/10 12:00 a.m.•4 views

CVE-2025-27255: Use of Hard-coded Credentials

Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code...

8CVSS7.4AI score0.00152EPSS
SaveExploits0References1
Pen Test Partners Blog
Pen Test Partners Blog
•added 2024/11/05 6:35 a.m.•32 views

Maritime lawyers assemble!

Maritime cyber insurance has been playing catch-up with maritime cyber security for a while now. It was all pretty good until the availability of cheap VSAT meant that ships became constantly connected. Vessels were mostly not connected at sea, other than Fleet Broadband connections, rarely used...

7.4AI score
SaveExploits0
Pen Test Partners Blog
Pen Test Partners Blog
•added 2024/11/05 6:14 a.m.•28 views

What goes into testing a ship?

TL;DR Testing a ship involves identifying and mitigating cybersecurity risks using the "Identify, Prevent, Detect, Respond, Recover" framework. Guidelines include MSC.42898, BIMCO, IACS UR E26/E27, and ISO standards. New builds and existing vessels require proper documentation and network securit...

8AI score
SaveExploits0
Pen Test Partners Blog
Pen Test Partners Blog
•added 2024/07/08 5:11 a.m.•17 views

Pen testing cruise ships

New build ships contracted for build from 1st July 2024 must comply with IACS UR E26 & 27. What does this mean for assessing the cyber security of a cruise ship? What’s the risk profile? Cruise ships have a unique risk profile. This is due to the huge number of guests on board, highly complex...

7.8AI score
SaveExploits0
Rows per page
Query Builder