Lucene search
+L

7366 matches found

Prion
Prion
added 2019/11/21 8:15 p.m.18 views

Design/Logic Flaw

When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 and prior and TwinCAT 3.1 version 4204.0 and prior...

5CVSS7.4AI score0.01427EPSS
SaveExploits1References2Affected Software1
CVE
CVE
added 2019/11/21 7:16 p.m.87 views

CVE-2019-5637

CVE-2019-5637 affects Beckhoff TwinCAT Profinet driver. A malformed UDP packet on the network can cause denial of service of the controller, impacting TwinCAT 2 (build 2304 and earlier) and TwinCAT 3.1 (build 4204.0 and earlier). The available documents confirm the vulnerability details and affec...

7.5CVSS7.4AI score0.01427EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
added 2019/11/21 7:16 p.m.32 views

CVE-2019-5636 Beckhoff TwinCAT Discovery Service Denial of Service

When a Beckhoff TwinCAT Runtime receives a malformed UDP packet, the ADS Discovery Service shuts down. Note that the TwinCAT devices are still performing as normal. This issue affects TwinCAT 2 version 2304 and prior and TwinCAT 3.1 version 4204.0 and prior...

5.3CVSS7.6AI score0.01427EPSS
SaveExploits1References2
CVE
CVE
added 2019/11/21 7:16 p.m.90 views

CVE-2019-5636

CVE-2019-5636: A Beckhoff TwinCAT Runtime can trigger a shutdown of the ADS Discovery Service when receiving a malformed UDP packet, while TwinCAT devices continue functioning. Affected: TwinCAT 2 v2304 and earlier; TwinCAT 3.1 v4204.0 and earlier. Root cause: malformed UDP handling leads to serv...

7.5CVSS6.3AI score0.01427EPSS
SaveExploits1References2Affected Software1
NVD
NVD
added 2019/11/14 5:15 p.m.13 views

CVE-2019-16110

The network protocol of Blade Shadow though 2.13.3 allows remote attackers to take control of a Shadow instance and execute arbitrary code by only knowing the victim's IP address, because packet data can be injected into the unencrypted UDP packet stream...

8.1CVSS8.4AI score0.01691EPSS
SaveExploits0References1
Prion
Prion
added 2019/11/14 5:15 p.m.18 views

Code injection

The network protocol of Blade Shadow though 2.13.3 allows remote attackers to take control of a Shadow instance and execute arbitrary code by only knowing the victim's IP address, because packet data can be injected into the unencrypted UDP packet stream...

6.8CVSS8.4AI score0.01691EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2019/11/14 4:56 p.m.53 views

CVE-2019-16110

Blade Shadow up to version 2.13.3 is vulnerable to remote code execution via the network protocol: an attacker who knows the victim’s IP can inject data into the unencrypted UDP stream, potentially taking control of a Shadow instance. Root cause: unprotected UDP packet handling allows arbitrary c...

8.1CVSS8.4AI score0.01691EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/11/14 4:56 p.m.26 views

CVE-2019-16110

The network protocol of Blade Shadow though 2.13.3 allows remote attackers to take control of a Shadow instance and execute arbitrary code by only knowing the victim's IP address, because packet data can be injected into the unencrypted UDP packet stream...

8.4AI score0.01691EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.33 views

EulerOS 2.0 SP5 : memcached (EulerOS-SA-2019-2213)

According to the versions of the memcached package installed, the EulerOS installation on the remote host is affected by the following vulnerabilities : - Memcached version 1.5.5 contains an Insufficient Control of Network Message Volume Network Amplification, CWE-406 vulnerability in the UDP...

7.5CVSS7.8AI score0.88114EPSS
SaveExploits6References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Siemens Dk Uncontrolled Resource Consumption

A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller All versions, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 All versions, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P All versions, SIMATIC CFU PA All...

5CVSS1.5AI score0.02065EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.32 views

Siemens Siprotec Unspecified Vulnerability

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

7.8CVSS3.6AI score0.74497EPSS
SaveExploits7References7
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Rockwellautomation Rslinx Out-of-bounds Read

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sendin...

7.8CVSS1.5AI score0.03855EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.27 views

Rockwellautomation Rslinx Integer Overflow or Wraparound

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a...

7.8CVSS1.7AI score0.03855EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Rockwellautomation Rslinx Out-of-bounds Read

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram...

7.8CVSS1.3AI score0.03855EPSS
SaveExploits0References2
ThreatPost
ThreatPost
added 2019/11/04 5:30 p.m.49 views

Wizard Spider Upgrades Ryuk Ransomware to Reach Deep into LANs

The Ryuk ransomware has added two features to enhance its effectiveness: The ability to target systems that are in “standby” or sleep mode; and the use of Address Resolution Protocol ARP pinging to find drives on a company’s LAN. Both are employed after the initial network compromise of a victim...

7.4AI score
SaveExploits0References9
ThreatPost
ThreatPost
added 2019/10/15 9:01 p.m.61 views

On-Board 'Mystery Boxes' Threaten Global Shipping Vessels

Commercial shipping environments are rife with vulnerabilities, according to researchers – up to and including unpatched “mystery boxes” that no one knows anything about. “In every single nautical pen test to date we have unearthed a system or device, that of the few crew that were aware, no one...

SaveExploits0References6
NVD
NVD
added 2019/10/10 2:15 p.m.32 views

CVE-2019-10936

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition...

7.5CVSS7.5AI score0.02065EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/10/10 12:00 a.m.28 views

Cisco IOS XE Software NAT Session Initiation Protocol Application Layer Gateway DoS (cisco-sa-20190925-sip-alg)

According to its self-reported version, Cisco IOS XE Software is affected by a denial of service DoS vulnerability in the Network Address Translation NAT Session Initiation Protocl SIP Application Layer Gateway ALG. This allows an unauthenticated, remote attacker to cause an affected device to...

8.6CVSS7.8AI score0.01967EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2019/10/10 12:00 a.m.41 views

CVE-2019-10936

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition...

7.5CVSS7.5AI score0.02065EPSS
SaveExploits0References2
CVE
CVE
added 2019/10/10 12:00 a.m.163 views

CVE-2019-10936

Siemens PROFINET devices (e.g., SIMATIC ET200S/ET200SP and related ecosystem listed in the advisory plugins) are affected by CVE-2019-10936. The root cause is handling large amounts of specially crafted UDP packets, enabling an unauthenticated remote attacker to trigger a denial-of-service condit...

7.5CVSS7.5AI score0.02065EPSS
SaveExploits0References2Affected Software1
Rows per page
Query Builder