10 matches found
CVE-2025-67399
CVE-2025-67399 Vulnerability Summary The AIRTH Smart Home AQI Monitor uses a CB3S Bluetooth SoC based on the BK7231N chipset with Software version number: 2.1.17. By physically accessing the device and identifying the SoC, the exposed UART debug/programming pins were located using the publicly...
CVE-2025-65731
CVE-2025-65731 CWE-1191: On-Chip Debug and Test Interface With Improper Access Control UART Root Shell Access on D-Link DIR-605L Hardware F1, Firmware V6.02CN02 Summary A critical hardware security vulnerability has been identified in the D-Link DIR-605L router, Hardware Version F1, Firmware...
CVE-2026-38571: Cleartext Storage of Sensitive Information
Cleartext storage and exposure of WPA2 credentials, and missing authentication on the rr/wr memory read/write commands, in the unauthenticated UART debug console of the Tenda N300 F3 V603 allow a physically proximate attacker to obtain stored WPA2 credentials in cleartext and to read or write...
CVE-2026-30613: Exposure of Sensitive Information to an Unauthorized Actor
An information disclosure vulnerability exists in AZIOT 1 Node Smart Switch 16amp- WiFi/Bluetooth Enabled Software Version: 1.1.9 due to improper access control on the UART debug interface. An attacker with physical access can connect to the UART interface and obtain sensitive information from th...
CVE-2025-15083 TOZED ZLT M30s UART on-chip debug and test interface with improper access control
A vulnerability was determined in TOZED ZLT M30s up to 1.47. The affected element is an unknown function of the component UART Interface. Executing manipulation can lead to on-chip debug and test interface with improper access control. The physical device can be targeted for the attack. Attacks o...
CVE-2025-59447: Exposure of Sensitive System Information to an Unauthorized Control Sphere
The YoSmart YoLink Smart Hub device 0382 exposes a UART debug interface. An attacker with direct physical access can leverage this interface to read a boot log, which includes network access credentials...
CVE-2020-15483
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access...
CVE-2020-15483
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access...
CVE-2020-15483: Missing Authentication for Critical Function
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access...
PT-2020-14450 · Nescomed · Nescomed Multipara Monitor M1000
Name of the Vulnerable Software and Affected Versions: Nescomed Multipara Monitor M1000 devices affected versions not specified Description: An issue was discovered where the physical UART debug port on the devices provides a shell without requiring a password, giving complete access...