Lucene search
+L

2 matches found

VulnCheck KEV
VulnCheck KEV
added 2018/12/20 12:00 a.m.8 views

VulnCheck KEV: CVE-2018-7522

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states...

7.2CVSS6.8AI score0.00431EPSS
SaveExploits0References1
OSV
OSV
added 2018/05/04 5:29 p.m.8 views

CVE-2018-8872

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory...

8.1CVSS5.8AI score0.02276EPSS
SaveExploits0References3