Lucene search
+L

240 matches found

Prion
Prion
added 2023/07/05 8:15 p.m.21 views

Design/Logic Flaw

The websocket configuration endpoint of the Loxone Miniserver Go Gen.2 before 14.1.5.9 allows remote authenticated administrators to inject arbitrary OS commands via the timezone parameter...

5.8CVSS6.8AI score0.0137EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
added 2023/07/05 12:0 a.m.29 views

CVE-2023-36622

The websocket configuration endpoint of the Loxone Miniserver Go Gen.2 before 14.1.5.9 allows remote authenticated administrators to inject arbitrary OS commands via the timezone parameter...

7.1AI score0.0137EPSS
SaveExploits1References2
CNNVD
CNNVD
added 2023/07/05 12:0 a.m.8 views

Loxone Miniserver 操作系统命令注入漏洞

Loxone Miniserver is a server from Loxone, Inc. that automates equipment in buildings, houses, and homes to provide energy management, monitoring, and other functions. A security vulnerability exists in Loxone Miniserver Go Gen.2 versions prior to 14.1.5.9, which stems from a websocket...

7.2CVSS7.4AI score0.0137EPSS
SaveExploits1References3
VulnCheck KEV
VulnCheck KEV
added 2023/06/22 12:0 a.m.11 views

VulnCheck KEV: CVE-2022-45699

Command injection in the administration interface in APSystems ECU-R version 5203 allows a remote unauthenticated attacker to execute arbitrary commands as root using the timezone parameter...

9.8CVSS7.6AI score0.76604EPSS
SaveExploits1References1
ATTACKERKB
ATTACKERKB
added 2023/06/02 8:15 p.m.4 views

CVE-2023-33669

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function...

9.8CVSS7.4AI score0.02089EPSS
SaveExploits2References3
NVD
NVD
added 2023/06/02 8:15 p.m.48 views

CVE-2023-33669

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function...

9.8CVSS9.7AI score0.02089EPSS
SaveExploits2References2
OSV
OSV
added 2023/06/02 8:15 p.m.5 views

CVE-2023-33669

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function...

9.8CVSS5.9AI score0.02089EPSS
SaveExploits2References2
Prion
Prion
added 2023/06/02 8:15 p.m.24 views

Stack overflow

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function...

7.5CVSS9.6AI score0.02089EPSS
SaveExploits2References2Affected Software1
CVE
CVE
added 2023/06/02 12:0 a.m.165 views

CVE-2023-33669

CVE-2023-33669 affects the Tenda AC8 router firmware (versions prior to V4.0-V16.03.34.06). The vulnerability is a stack overflow in the timeZone handling path (sub_44db3c), which can lead to arbitrary code execution or a denial of service. Public references describe the issue consistently, with ...

9.8CVSS9.6AI score0.02089EPSS
SaveExploits2References2Affected Software1
Cvelist
Cvelist
added 2023/06/02 12:0 a.m.30 views

CVE-2023-33669

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function...

9.9AI score0.02089EPSS
SaveExploits2References2
Vulnrichment
Vulnrichment
added 2023/06/02 12:0 a.m.13 views

CVE-2023-33669

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub44db3c function...

9.7AI score0.02089EPSS
SaveExploits2References2
CNNVD
CNNVD
added 2023/06/02 12:0 a.m.9 views

Tenda AC8 缓冲区错误漏洞

Tenda AC8 is a wireless router from Tenda, a Chinese company. A stack overflow vulnerability exists in the Tenda AC8 timeZone parameter, which can be exploited by an attacker to cause a buffer overflow and execute arbitrary code on the system, or cause a denial of service...

9.8CVSS8.1AI score0.02089EPSS
SaveExploits2References3
Vulnrichment
Vulnrichment
added 2023/03/14 12:0 a.m.9 views

CVE-2023-28343

OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/settimezone timezone parameter, because of settimezone in models/managementmodel.php...

9.8AI score0.85332EPSS
SaveExploits5References3
SUSE CVE
SUSE CVE
added 2023/02/15 5:25 a.m.6 views

SUSE CVE-2014-9220

SQL injection vulnerability in OpenVAS Manager before 4.0.6 and 5.x before 5.0.7 allows remote attackers to execute arbitrary SQL commands via the timezone parameter in a modifyschedule OMP command...

7.5CVSS8.8AI score0.02065EPSS
SaveExploits0References3
NVD
NVD
added 2023/02/10 2:15 a.m.32 views

CVE-2022-45699

Command injection in the administration interface in APSystems ECU-R version 5203 allows a remote unauthenticated attacker to execute arbitrary commands as root using the timezone parameter...

9.8CVSS10AI score0.76604EPSS
SaveExploits1References3
Cvelist
Cvelist
added 2023/02/10 12:0 a.m.37 views

CVE-2022-45699

Command injection in the administration interface in APSystems ECU-R version 5203 allows a remote unauthenticated attacker to execute arbitrary commands as root using the timezone parameter...

10AI score0.76604EPSS
SaveExploits1References3
CNNVD
CNNVD
added 2023/02/10 12:0 a.m.8 views

APsystems Energy Communication Unit 操作系统命令注入漏洞

The APsystems Energy Communication Unit APsystems ECU-R is an energy communication unit from APsystems USA. An operating system command injection vulnerability exists in APSystems ECU-R version 5203. An attacker could exploit this vulnerability to execute arbitrary commands as root using the...

9.8CVSS8.9AI score0.76604EPSS
SaveExploits1References4
OSV
OSV
added 2022/12/02 6:15 p.m.3 views

CVE-2022-45655

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the formfastsettingwifiset function...

7.5CVSS6.2AI score0.00815EPSS
SaveExploits1References1
Prion
Prion
added 2022/12/02 6:15 p.m.19 views

Buffer overflow

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the formfastsettingwifiset function...

5CVSS7.8AI score0.00815EPSS
SaveExploits1References1Affected Software1
Vulnrichment
Vulnrichment
added 2022/12/02 12:0 a.m.7 views

CVE-2022-45655

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the formfastsettingwifiset function...

7.8AI score0.00815EPSS
SaveExploits1References1
Rows per page
Query Builder