CISA Releases Four Industrial Control Systems Advisories

CISA released four Industrial Control Systems ICS advisories on August 19, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-231-01 Siemens Desigo CC Product Family and SENTRON Powermanager ICSA-25-231-02 Siemen...

7.1AI score
Exploits0References4
BDU FSTEC
BDU FSTEC
added 2025/08/11 12:0 a.m.12 views

The vulnerability of the DEVICE_PING command in the monitoring and control software for solar energy systems, Tigo Cloud Connect Advanced (CCA), allows a hacker to gain unauthorized access to protected information, execute arbitrary commands, or cause service interruptions.

The vulnerability of the DEVICEPING command in the monitoring and management tool for solar energy systems, Tigo Cloud Connect Advanced CCA, is related to the lack of data cleaning at the control level during the processing of the final endpoint /cgi-bin/mobileapi. Exploiting this vulnerability c...

9CVSS5.8AI score0.15849EPSS
Exploits2References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2025/08/11 12:0 a.m.15 views

The vulnerability of the monitoring and control device for solar energy systems, Tigo Cloud Connect Advanced (CCA), arises from the use of strictly encrypted account data. This allows attackers to circumvent security restrictions, gain increased privileges, and obtain full control over the device.

The vulnerability of the monitoring and control device for solar energy systems, Tigo Cloud Connect Advanced CCA, lies in the use of strictly encrypted account data. Exploiting this vulnerability allows a malicious actor to bypass security restrictions, gain increased privileges, and obtain full...

10CVSS5.5AI score0.00531EPSS
Exploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2025/08/11 12:0 a.m.12 views

The vulnerability of the monitoring and control tool for solar energy systems, Tigo Cloud Connect Advanced (CCA), arises from incorrect generation of session identifiers. This allows attackers to gain unauthorized access to protected information.