11880 matches found
Siemens SIMATIC Devices NULL Pointer Dereference (CVE-2023-52458)
In the Linux kernel, the following vulnerability has been resolved: block: add check that partition length needs to be aligned with block size This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2024-35915)
nfc: nci: Fix uninit-value in ncidevup and ncintfpacket This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503499; scriptversion"1.2";...
Siemens SIMATIC Devices Use After Free (CVE-2024-50150)
In the Linux kernel, the following vulnerability has been resolved: usb: typec: altmode should keep reference to parent The altmode device release refers to its parent device, but without keeping a reference to it. When registering the altmode, get a reference to the parent and put it in the...
Siemens SIMATIC Devices Missing Release of Memory after Effective Lifetime (CVE-2024-35930)
scsi: lpfc: Fix possible memory leak in lpfcrcvpadisc This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503546; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Locking (CVE-2025-21859)
USB: gadget: fmidi: fmidicomplete to call queuework This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503474; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-36007)
In the Linux kernel, the following vulnerability has been resolved: mlxsw: spectrumacltcam: Fix warning during rehash As previously explained, the rehash delayed work migrates filters from one region to another. This is done by iterating over all chunks all the filters with the same priority in t...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Out-of-bounds Read (CVE-2024-40941)
wifi: iwlwifi: mvm: don't read past the mfuart notifcation. In case the firmware sends a notification that claims it has more data than it has, it will read past that was allocated for the notification. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-...
Siemens SIMATIC Devices Improper Validation of Array Index (CVE-2024-43858)
In the Linux kernel, the following vulnerability has been resolved: jfs: Fix array-index-out-of-bounds in diFree This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-38599)
jffs2: prevent xattr node from overflowing the eraseblock Add a check to make sure that the requested xattr node size is no larger than the eraseblock minus the cleanmarker. Unlike the usual inode nodes, the xattr nodes aren't split into parts and spread across multiple eraseblocks, which means...
Siemens SIMATIC Devices Use After Free (CVE-2024-27396)
In the Linux kernel, the following vulnerability has been resolved: net: gtp: Fix Use-After-Free in gtpdellink Since callrcu, which is called in the hlistforeachentryrcu traversal of gtpdellink, is not part of the RCU read critical section, it is possible that the RCU grace period will pass durin...
Siemens SIMATIC Devices Incorrect Calculation of Buffer Size (CVE-2024-42259)
In the Linux kernel, the following vulnerability has been resolved: drm/i915/gem: Fix Virtual Memory mapping boundaries calculation Calculating the size of the mapped area as the lesser value between the requested size and the actual size does not consider the partial mapping offset. This can cau...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-40993)
netfilter: ipset: suspicious rcudereferenceprotected. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503718; scriptversion"1.2";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-26875)
media: pvrusb2: fix uaf in pvr2contextsetnotify. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503541; scriptversion"1.2";...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Resource Shutdown or Release (CVE-2024-41006)
netrom: a memory leak in nrheartbeatexpiry. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503530; scriptversion"1.3";...
Siemens SIMATIC Devices Use of Uninitialized Resource (CVE-2025-21862)
dropmonitor: incorrect initialization order. If dropmonitor is built as a kernel module, syzkaller may have time to send a netlink NETDMCMDSTART message during the module loading. This will call the netdmmonitorstart function that uses a spinlock that has not yet been initialized. This plugin onl...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-39468)
smb: client: Deadlock in smb2findsmbtcon. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503588; scriptversion"1.3";...
Siemens SIMATIC Devices Improper Input Validation (CVE-2024-35845)
wifi: iwlwifi: dbg-tlv: ensure NUL termination The iwlfwinidebuginfotlv is used as a string, so we must ensure the string is terminated correctly before using it. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Resource Locking (CVE-2024-47660)
In the Linux kernel, the following vulnerability has been resolved: fsnotify: clear PARENTWATCHED flags lazily In some setups directories can have many usually negative dentries. Hence fsnotifyupdatechilddentryflags function can take a significant amount of time. Since the bulk of this function...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Allocation of Resources Without Limits or Throttling (CVE-2024-42082)
xdp: unused WARN in xdpregmemmodel. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503577; scriptversion"1.3";...
Siemens SIMATIC Devices NULL Pointer Dereference (CVE-2025-21666)
vsock: prevent null-ptr-deref in vsockhasdata|hasspace This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503539; scriptversion"1.2";...