Yokogawa Vnet/IP Open Communication Driver Resource Management Errors (CVE-2018-16196)
Multiple Yokogawa products that contain Vnet/IP Open Communication Driver CENTUM CS 3000R3.05.00 - R3.09.50, CENTUM CS 3000 Entry ClassR3.05.00 - R3.09.50, CENTUM VPR4.01.00 - R6.03.10, CENTUM VP Entry ClassR4.01.00 - R6.03.10, ExaopcR3.10.00 - R3.75.00, PRMR2.06.00 - R3.31.00, ProSafe-RSR1.02.00...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14465)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwell Automation MicroLogix Controllers and RSLogix 500 Software Use of Hard-Coded Cryptographic Key (CVE-2020-6990)
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file...
ABB FOX515T Improper Input Validation (CVE-2017-14025)
An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrie...
Rockwell Automation MicroLogix Improper Authentication (CVE-2017-12088)
An exploitable denial of service vulnerability exists in the Ethernet functionality of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted packet can cause a device power cycle resulting in a fault state and deletion of ladder logic. An attacker can send one...
Schneider Electric Modicon Quantum Improper Access Control (CVE-2019-6815)
In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-400 CPU Improper Input Validation (CVE-2018-4850)
A vulnerability has been identified in SIMATIC S7-400 incl. F CPU hardware version 4.0 and below All versions, SIMATIC S7-400 incl. F CPU hardware version 5.0 All firmware versions V5.2, SIMATIC S7-400H CPU hardware version 4.5 and below All versions. The affected CPUs improperly validate S7...
Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Improper Neutralization of Special Elements Used in an OS Command (CVE-2019-14931)
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's...
Schneider Electric Controller Asset Information
It is possible to obtain attributes of the remote Schneider Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...
Schneider Electric Modicon Path Traversal (CVE-2014-0754)
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...
Siemens SIMATIC CP 343-1/CP 443-1 Modules and SIMATIC S7-300/S7-400 CPUs (CVE-2016-8672)
A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...
Rockwell Automation ControlLogix 5580 and CompactLogix 5380 Uncontrolled Resource Consumption (CVE-2017-6024)
A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause...
Siemens Integer Underflow in Wind River VxWorks (CVE-2019-12255)
Wind River VxWorks has a Buffer Overflow in the TCP component issue 1 of 4. This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. C...
Schneider Electric Modicon Out-of-bounds Read (CVE-2021-22790)
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BMEP and BMEH, all versions, Modicon M340 CPU part...
Siemens S7-1200 and S7-200 SMART CPUs Exposed Dangerous Method or Function (CVE-2019-13945)
A vulnerability has been identified in SIMATIC S7-1200 CPU family incl. SIPLUS variants All versions, SIMATIC S7-1200 CPU family V4.x incl. SIPLUS variants All versions, SIMATIC S7-1200 CPU family V4.x incl. SIPLUS variants All versions with Function State FS 11, SIMATIC S7-200 SMART CPU CR20s 6E...
Siemens S7-300/400 PLC (CVE-2016-9158)
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
Schneider Electric Modicon Cross-site Scripting (CVE-2012-0930)
Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...
Schneider Electric Modicon Arbitrary Code Execution (CVE-2013-0664)
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests...
Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension Missing Authentication For Critical Function (CVE-2018-4838)
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module DNP3 variant All versions V1.04, EN100 Ethernet module PROFINET IO variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module IEC 104...