661 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56586)
f2fs: fix f2fsbugon when uninstalling filesystem call f2fsevictinode. creating a large files during checkpoint disable until it runs out of space and then delete it, then remount to enable checkpoint again, and then unmount the filesystem triggers the f2fsbugon. This plugin only works with...
Siemens SICAM Q100/Q200 Cleartext Storage of Sensitive Information (CVE-2025-40752)
Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46721)
apparmor: fix possible NULL pointer dereference. profile-parent-dentsAAFSPROFDIR could be NULL only if its parent is made from createmissingancestors.. and 'ent-old' is NULL in aareplaceprofiles... In that case, it must return an error code and the code, -ENOENT represents its state that the path...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42153)
i2c: pnx: potential deadlock warning from deltimersync call in isr. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504657; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Integer Overflow or Wraparound (CVE-2024-53145)
um: potential integer overflow during physmem setup. This vulnerability happens when the real map size is greater than LONGMAX, which can be easily triggered on UML/i386. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56659)
net: lapb: It is unclear if net/lapb code is supposed to be ready for 8021q, this may lead to crashes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens APOGEE PXC and TALON TC Series Expected Behavior Violation (CVE-2025-40555)
Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50295)
net: arc: A warning is shown because ndev-dev and pdev-dev are not the same device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504563;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Initialization (CVE-2024-50193)
x86/entry32: Clear CPU buffers after register restore in NMI return CPU buffers are currently cleared after call to excnmi, but before register state is restored. This may be okay for MDS mitigation but not for RDFS. Because RDFS mitigation requires CPU buffers to be cleared when registers don't...
Siemens SCALANCE and RUGGEDCOM Devices Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') (CVE-2024-40902)
jfs: xattr: buffer overflow for invalid xattr. When an xattr size is not what is expected, it is printed out to the kernel log in hex format as a form of debugging. But when that xattr size is bigger than the expected size, printing it out can cause an access off the end of the buffer. This plugi...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56598)
jfs: array-index-out-of-bounds fix in dtReadFirst. The value of stbl can be sometimes out of bounds due to a bad filesystem. Added a check with appopriate return of error code in that case. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53146)
NFSD: Prevent a potential integer overflow If the tag length is = U32MAX - 3 then the length + 4 addition can result in an integer overflow. Address this by splitting the decoding into several steps so that decodecbcompound4res does not have to perform arithmetic on the unsafe length value. This...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56633)
tcpbpf: The current sk memory accounting logic in SKREDIRECT is pre-uncharging tosend bytes, which is either msg-sg.size or a smaller value applybytes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49965)
ocfs2: remove unreasonable unlock in ocfs2readblocks Patch series Misc fixes for ocfs2readblocks, v5. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50179)
ceph: incorrect Fw reference check when dirtying pages. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504801; scriptversion"1.3";...
Siemens SIPROTEC 5 Use of Http Request with Sensitive Query String (CVE-2025-40742)
The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. This plugin only works with Tenable.ot...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-45003)
vfs: Some filesystemseg. ext4 with eainode feature, ubifs with xattr may do inode lookup in the inode evicting callback function, if the inode lookup is operated under the inode lru traversing context, deadlock problems may happen. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53103)
hvsock: Initializing vsk-trans to NULL to prevent a dangling pointer When hvs is released, there is a possibility that vsk-trans may not be initialized to NULL, which could lead to a dangling pointer. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50059)
ntb: ntbhwswitchtec: use after free vulnerability in switchtecntbremove due to race condition. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50180)
"fbdev: sisfb: Fix strbuf array overflow. The values of the variables xres and yres are placed in strbuf. These variables are obtained from strbuf1. The strbuf1 array contains digit characters and a space if the array contains non-digit characters. Then, when executing sprintfstrbuf, %ux%ux8, xre...